Inspection History Details
Inspection Status: Correction Required
Inspection History: PLUMBING - FINAL
Permit Number - T19CM00349
Inspection Description - PLUMBING - FINAL
Inspection Status - Correction Required
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/08/2019 | PLUMBING - FINAL | Correction Required | Water Heater. P&T drain line to be 3/4 inch interior diameter and no PVC. Drip req on gas supply line . Thimble at ceiling req for B vent clearance per manufacturer. 3 Tec screws req at vent connector to B vent and B vent to water heater draft hood. Combustion air required at door. 100 sq in within 12 in of the ceiling and within 12 in of the floor. |