Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Submitted
Type:
Sign - Permanent
Address:
735 N 4TH AV
Apply Date:
11/13/2018
Applicant:
Description:
Illuminated wall sign - requires historic review (28.3 sqft)

Outstanding Inspections

Permit Status: Submitted
Permit Number: T18OT01181
Permite Description: Illuminated wall sign - requires historic review (28.3 sqft)
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
12/19/2018 COT - ENGR - Signage Final N/A Complete (Recurring) {Activity date: 12/17/2018; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - Received revised plans via email (from unverified party as to relationship with contractor). Emailed and copied contractor as to permissions to submit in contractor's name to proceed with review (plans had contractor's name on them, not submitting party).} ; {Activity date: 12/19/2018; Status: Continued; Inspector: Hthrall; Comment: Entered by HTHRALL1 - RE: review of resubmitted plan set (requires historic review)
AT: 735 N 4th Ave
Sign permit: T18OT01181
Reviewer: H. Thrall
Date: 12/19/18 (date plans also received by Trademark Visual)

1) Provide size/type of fasteners on the plan.
2) Provide notation on the plan: "maximum internally illuminated sign color temperature 4400k"

Emailed back notation to contractor. Contractor also included Historic application. Will forward to historic with plans for file. Contractor to mail in a check for full historic review process.} ; {Activity date: 11/13/2018; Status: Correction Required; Inspector: Hthrall; Comment: Entered by HTHRALL1 - RE: sign permit review
FOR: new illuminated wall sign - east elev
AT: 735 N 4th Av
Sign Permit: T18OT01181
ZONING: HC-3 / West University / Historic - needs committee review
Reviewers: B.Wiese / H.Thrall

The drawing received for the lighting/mounting was not clear, please pardon if any of the following comments are listed, as reviewers were unable to determine the full spectrum of information the way the detail was provided.

1) Per Outdoor Lighting Code (OLC) Section 403.5, provide 24 hour time clock and note location on plan for inspections.

2) Per OLC Section 501.3.2 - note on plan maximum color temperature of an internally illuminated sign is 4400K.

3) NEC 600 - clearly call out the location of the disconnect switch. Sign to be on isolated circuit, state on plans.
A) specify volts, amps, cirucits on the plans (NEC 600)

4) Provide clearly labeled, enlarged and darkened diagram of the channel letter and logo mounted to wall.

A) specify wall surface
B) specify number of penetrations total - note, this will be important for historic review of this location
C) specify type of mounting suitable for the sign to the wall type
D) check height off the ground for the sign - scale appears that the height is greater - or check the way the photo was applied.

5) This site is zoned HC-3 and within the West University Historic District. Once corrected plans are received, the project can be referred for historic review process. (Note, sign area proposed within allowance for HC-3 zone/sign district.) Please send revisions to Heather.Thrall@tucsonaz.gov

}