Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T18CM10091
Permit Details
Apply Date:
12/31/2018
Applicant:
JON TOTEL - ONE ARCHITECTURE
Description:
4 STORY HILTON HOTEL
Architects:
- BRUBAKER, DONALD ROY JR.
Contractors:
- EBCO GENERAL CONTRACTOR LTD
Permit Reviews
Permit Number - T18CM10091
Permit Status: C of o
Permit Description: 4 STORY HILTON HOTEL
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/02/2018 | COMMERCIAL - NEW | 03/05/2019 | COMPLETED |
03/31/2020 | REVISION - - 1ST | 06/03/2020 | COMPLETED |
04/30/2019 | RESUBMITTAL | 07/25/2019 | COMPLETED |
07/25/2019 | RESUBMITTAL | 01/09/2020 | COMPLETED |
08/14/2020 | REVISION - - 3RD | 08/31/2020 | COMPLETED |
12/31/2018 | PLANS OK TO SUBMIT - COMM | 01/03/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T18CM10091
Permit Status: C of o
Permit Description: 4 STORY HILTON HOTEL
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
12/31/2018 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T18CM10091
Permit Description: 4 STORY HILTON HOTEL
Total Completed Inspections - 51
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/20/2020 | PLUMBING - PRE SLAB | TVALENCIA | Approved | |
03/20/2020 | PLUMBING - ROUGH, SOIL | TVALENCIA | Approved | |
03/20/2020 | BUILDING PRE-SLAB | TVALENCIA | Approved | |
03/20/2020 | EXCAVATION/LAYOUT REBAR & ZON | TVALENCIA | Approved | |
05/22/2020 | ROOF NAILING | DMUNIZ | Approved | |
07/07/2020 | PLUMBING - INTERMEDIATE | TVALENCIA | Approved | partial |
07/28/2020 | STUCCO MESH | TVALENCIA | Approved | approved |
08/20/2020 | ELECTRIC - INTERMEDIATE | TTREMBULAK | Approved | Approved |
08/21/2020 | SITE - SEWER | DMUNIZ | Approved | Approved |
08/31/2020 | PLUMBING - YARD WTR LINE/TEST | DMUNIZ | Approved | Approved. |
10/26/2020 | ELECTRIC - PROGRESS | DQUINN | Approved | Approved, completion of light pole caissons and uffers ok for concrete placement. |
10/28/2020 | ELECTRIC - UNDERGROUND | DMUNIZ | Approved | Approved |
10/28/2020 | ELECTRIC - UFER | DMUNIZ | Approved | APPROVED |
10/28/2020 | ELECTRIC - CONSTRUCTION POWER | DMUNIZ | Approved | Approved, 120/208V, 2500AMP SES Inspected and Approved for TEP Clearance ECO. |
10/30/2020 | PLUMBING - GAS PRESSURE TEST | DMUNIZ | Approved | Approved, Clear Southwest Gas |
11/13/2020 | GAS CLEARANCE | DMUNIZ | Approved | CODE |
11/13/2020 | PLUMBING - GAS PRESS TEST FNL | DMUNIZ | Approved | Approved, Clear Southwest Gas |
11/18/2020 | MECHANICAL - ABOVE CEILING | DMUNIZ | Approved | |
11/18/2020 | PLUMBING - ABOVE CEILING | DMUNIZ | Approved | |
11/18/2020 | ELECTRIC - ABOVE CEILING | DMUNIZ | Approved | |
11/18/2020 | BUILDING ABOVE CEILING | DMUNIZ | Approved | |
12/10/2020 | TEP CLEARANCE - PM | RBOOHER | Approved | CODE INCR |
12/17/2020 | U VALUE FOR WINDOW | DMUNIZ | Approved | Approved. |
12/18/2020 | SHEET ROCK NAILING | DMUNIZ | Approved | Approved. |
12/18/2020 | EXT METAL CLIPS/EXT SHEATHING | DMUNIZ | Approved | Approved. |
12/18/2020 | FRAMING | DMUNIZ | Approved | Approved. |
12/18/2020 | PLUMBING - PROGRESS | DMUNIZ | Approved | Approved. |
12/18/2020 | FIREWALL/FIREBARRIER/FIRESTOP | DMUNIZ | Approved | Approved. |
12/18/2020 | BUILDING - PROGRESS | DMUNIZ | Approved | Approved. |
12/18/2020 | MECHANICAL - PROGRESS | DMUNIZ | Approved | Approved. |
12/18/2020 | ELECTRIC - SERVICE UPGRADE | DMUNIZ | Approved | Approved. |
12/23/2020 | ELECTRIC - FINAL | DUMUNIZ | Approved | Partial, 1st floor Guest rooms complete & ok to stock. |
12/23/2020 | PLUMBING - FINAL | DUMUNIZ | Approved | Partial, 1st floor Guest rooms complete & ok to stock. |
12/23/2020 | MECHANICAL - FINAL | DUMUNIZ | Approved | Partial, 1st floor Guest rooms complete & ok to stock. |
12/23/2020 | MECHANICAL - INTERMEDIATE | DUMUNIZ | Approved | Approved. |
01/13/2021 | FIRE - ALARM FINAL | CBASALDUA | Approved | |
01/13/2021 | FIRE SPKLR - FINAL | CBASALDUA | Approved | |
02/11/2021 | MECHANICAL - HOODS | TTREMBULAK | Approved | APPROVED |
02/11/2021 | PLUMBING - ROOF DRAINS | TTREMBULAK | Approved | APPROVED |
02/11/2021 | ELECTRIC - OUTDOOR LIGHTING | TTREMBULAK | Approved | APPROVED |
02/11/2021 | OUTDOOR LIGHTING FINAL | TTREMBULAK | Approved | APPROVED |
02/12/2021 | POOL/SPA HEATER | WGALLAGHER | Approved | APPROVED SEE T20BU00300 |
02/12/2021 | POOL/SPA FINAL/BARRIER | WGALLAGHER | Approved | APPROVED |
02/12/2021 | POOL/SPA GAS | WGALLAGHER | Approved | APPROVED |
02/12/2021 | POOL/SPA ELECTRIC | WGALLAGHER | Approved | APPROVED SEE T20BU00300 |
02/12/2021 | POOL/SPA PLUMBING | WGALLAGHER | Approved | APPROVED, SEE T20BU00300 |
02/23/2021 | FIRE - FINAL | CBASALDUA | Approved | |
02/24/2021 | PLUMBING - BACK WATER VALVE | KCOCO | Approved | APPROVED |
03/11/2021 | ENGINEERING - FINAL | DROBERTS | Approved | |
03/12/2021 | CERTIFICATE OF OCCUPANCY | DROBERTS | Approved | |
03/12/2021 | BUILDING - FINAL | DROBERTS | Approved |