Permit: T18CM08907
Permit Details
Status:
C of o
Type:
MULTI FAMILY NEW
Address:
1330 E DRACHMAN ST BLDG#1
Address NEW:
1330 E DRACHMAN ST BLDG#1
Apply Date:
11/08/2018
Applicant:
N/A
Description:
MFR JMFR404718 T18-M0075
Architects:
- MEYER WILLIAM (CHUCK)
Contractors:
- STRASSER & ASSOCIATES INCORPORATED
Permit Reviews
Permit Number - T18CM08907
Permit Status: C of o
Permit Description: MFR JMFR404718 T18-M0075
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/08/2018 | COMMERCIAL - BLDG/FIRE/ZONING/ENG | 08/23/2019 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T18CM08907
Permit Status: C of o
Permit Description: MFR JMFR404718 T18-M0075
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/08/2018 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T18CM08907
Permit Description: MFR JMFR404718 T18-M0075
Total Completed Inspections - 37
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/19/2018 | PLUMBING - ROUGH, SOIL | DMCCARTHY | Approved | |
| 11/19/2018 | PLUMBING - PRE SLAB | DMCCARTHY | Approved | Building 1 5plex B#1101 to 1105 |
| 11/30/2018 | ELECTRIC - UNDERGROUND | JBURGE | Approved | |
| 11/30/2018 | ELECTRIC - UFER | JBURGE | Approved | |
| 11/30/2018 | BUILDING PRE-SLAB | JBURGE | Approved | |
| 11/30/2018 | EXCAVATION/LAYOUT REBAR & ZON | JBURGE | Approved | |
| 02/14/2019 | ROOF NAILING | ESTEVENS | Approved | |
| 02/27/2019 | EXT METAL CLIPS/EXT SHEATHING | ESTEVENS | Approved | |
| 03/11/2019 | ELECTRIC - ABOVE CEILING | ESTEVENS | Approved | |
| 03/11/2019 | ELECTRIC - INTERMEDIATE | ESTEVENS | Approved | |
| 03/14/2019 | PLUMBING - ABOVE CEILING | ESTEVENS | Approved | |
| 03/14/2019 | PLUMBING - INTERMEDIATE | ESTEVENS | Approved | |
| 03/25/2019 | STUCCO MESH | RCHANDLER | Approved | |
| 03/26/2019 | MECHANICAL - ABOVE CEILING | ESTEVENS | Approved | |
| 03/26/2019 | MECHANICAL - INTERMEDIATE | ESTEVENS | Approved | |
| 03/26/2019 | MECHANICAL - UNDERGROUND | ESTEVENS | Approved | |
| 03/26/2019 | FIREWALL/FIREBARRIER/FIRESTOP | ESTEVENS | Approved | |
| 03/26/2019 | FRAMING | ESTEVENS | Approved | |
| 04/16/2019 | SHEET ROCK NAILING | JBURGE | Approved | Ok to tape throughout. |
| 04/29/2019 | PLUMBING - MD GAS/PRECONST MTG | ESTEVENS | Approved | |
| 04/29/2019 | PLUMBING - SEWER HCS CONNECT | ESTEVENS | Approved | |
| 05/01/2019 | STEM WALL/RETAINING WALL | ESTEVENS | Approved | |
| 05/28/2019 | U VALUE FOR WINDOW | TVALENCIA | Approved | |
| 06/19/2019 | TEP CLEARANCE - PM | ESTEVENS | Approved | Units #1101, 1102, 1103, 1104, 1105 & house panel. CODE ECO |
| 06/19/2019 | ELECTRIC - CABLE DROP | ESTEVENS | Approved | The TEP clearance code is ECO. Units #1101, 1102, 1103, 1104, 1105 & house panel. |
| 07/24/2019 | PLUMBING - BACK WATER VALVE | ESTEVENS | Approved | |
| 07/24/2019 | PLUMBING - YARD WTR LINE/TEST | ESTEVENS | Approved | |
| 07/24/2019 | OUTDOOR LIGHTING FINAL | ESTEVENS | Approved | |
| 07/24/2019 | ELECTRIC - FINAL | ESTEVENS | Approved | |
| 07/24/2019 | ELECTRIC - OUTDOOR LIGHTING | ESTEVENS | Approved | |
| 07/24/2019 | BUILDING ABOVE CEILING | ESTEVENS | Approved | |
| 07/26/2019 | MECHANICAL - FINAL | ESTEVENS | Approved | |
| 07/29/2019 | PLUMBING - FINAL | RSHERRY | Approved | REVIEW OF WATER DISINFECTION REPORT COMPLETED |
| 08/22/2019 | FIRE - FINAL | MRoss | Approved | |
| 08/22/2019 | FIRE - ALARM FINAL | MRoss | Approved | |
| 08/22/2019 | FIRE SPKLR - FINAL | MRoss | Approved | |
| 08/23/2019 | BUILDING - FINAL | RSHERRY | Approved |