Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
1009 W HURON ST
Address NEW:
1009 W HURON ST
Apply Date:
10/05/2018
Applicant:
PIMA VENTURES LLC
Description:
REMODEL INTERIOR, NEW ELECTRIC SERVICE, NEW HEAT PUMP & DUCTWORK, NEW PLUMBING, AND NEW WINDOWS
Contractors:
  • PIMA VENTURES LLC

Permit Reviews

Permit Number - T18CM07935
Permit Status: Final
Permit Description: REMODEL INTERIOR, NEW ELECTRIC SERVICE, NEW HEAT PUMP & DUCTWORK, NEW PLUMBING, AND NEW WINDOWS
Start Date Submittal Complete Date Status  
10/05/2018 RESIDENTIAL - BLDG/ZONING-WALKTHRU 10/05/2018 COMPLETED Review Details
10/18/2018 REVISION - - 1ST 10/18/2018 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T18CM07935
Permit Status: Final
Permit Description: REMODEL INTERIOR, NEW ELECTRIC SERVICE, NEW HEAT PUMP & DUCTWORK, NEW PLUMBING, AND NEW WINDOWS
Total Outstanding Activity Conditions - 1
Date Name
10/05/2018 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T18CM07935
Permit Description: REMODEL INTERIOR, NEW ELECTRIC SERVICE, NEW HEAT PUMP & DUCTWORK, NEW PLUMBING, AND NEW WINDOWS
Total Completed Inspections - 15
Date Description Inspector Results Comments
12/05/2018 EXCAVATION/LAYOUT REBAR & ZON DMCCARTHY Approved customer canceled early this morning
12/12/2018 ELECTRIC - SERVICE UPGRADE DMCCARTHY Approved service entrance cable has already connected power powered up
Met foreman Outfront after inspection explain to him everything is not ready he doesn’t need a carbon copy and said that they should not have even called the inspections today and they’re not ready yet he’s gonna look into electrical Service upgrade details
12/12/2018 PLUMBING - ROUGH, SOIL DMCCARTHY Approved work is not ready for test
12/20/2018 MECHANICAL - INTERMEDIATE TVALENCIA Approved 1- Shall provide (3) sided blocking on all forced air vents.
Inspection stop!
12/20/2018 PLUMBING - INTERMEDIATE TVALENCIA Approved 1- Shallprovide a directional fitting for the tub waste line.
2- Fernco couplings are not approved within the structure, shall provide mission specialty couplings.
3- Shall provide a directional fitting for the laundry waste line.
4- Shall provide cast iron perm. caps for all dead end drains under the slab.
5- Threaded fittings not allowed in a concealed location at lavatory waste line.
6- 2 inch waste line can not be reduced to 11/2 inch existing waste line in wall.
7- Clothes washer stand pipe distance is 18 inches minimum and 42 inches maximum.
8- Shall provide a minimum of 18 inches if copper piping then tranation to pex at the water heater supplies.
9- Shall provide a directional fitting for the water closet and install in a conventional manner.
10- Shall provide tracer wire on bldg. Sewer.
11- Horizontal branch vent for the front bathroom lavatory shall be located a minimum of 6 inches above the flood level rim of the fixture.
12- Front bathroom tub requires a trap and vent.
13- Kitchen sink horizontal vent shall be located 6 inches above the flood level rim of the fixture.
12/20/2018 ELECTRIC - FINAL TVALENCIA Approved 1- Conductors and box devises in walls are okay
12/20/2018 BUILDING PRE-SLAB DQUINN Approved 1- Footing is missing steel reinforcement.
01/29/2019 PLUMBING - GAS PRESSURE TEST JBURGE Approved Gauge set at 10 psi.
02/12/2019 FRAMING TVALENCIA Approved
02/12/2019 ROOF NAILING TVALENCIA Approved
02/12/2019 EXT METAL CLIPS/EXT SHEATHING TVALENCIA Approved
04/04/2019 GAS CLEARANCE TVALENCIA Approved
04/04/2019 MECHANICAL - FINAL TVALENCIA Approved
04/04/2019 PLUMBING - FINAL TVALENCIA Approved
04/04/2019 BUILDING - FINAL TVALENCIA Approved