Permit: T18CM07935

Parcel: 116172210


Addresses:

1009 W HURON ST

Inspection Status: Approved

Inspection History: PLUMBING - INTERMEDIATE

Date Description Inspector Results Comments
01/29/2019 PLUMBING - INTERMEDIATE Approved
12/20/2018 PLUMBING - INTERMEDIATE Denied 1- Shallprovide a directional fitting for the tub waste line.
2- Fernco couplings are not approved within the structure, shall provide mission specialty couplings.
3- Shall provide a directional fitting for the laundry waste line.
4- Shall provide cast iron perm. caps for all dead end drains under the slab.
5- Threaded fittings not allowed in a concealed location at lavatory waste line.
6- 2 inch waste line can not be reduced to 11/2 inch existing waste line in wall.
7- Clothes washer stand pipe distance is 18 inches minimum and 42 inches maximum.
8- Shall provide a minimum of 18 inches if copper piping then tranation to pex at the water heater supplies.
9- Shall provide a directional fitting for the water closet and install in a conventional manner.
10- Shall provide tracer wire on bldg. Sewer.
11- Horizontal branch vent for the front bathroom lavatory shall be located a minimum of 6 inches above the flood level rim of the fixture.
12- Front bathroom tub requires a trap and vent.
13- Kitchen sink horizontal vent shall be located 6 inches above the flood level rim of the fixture.
12/12/2018 PLUMBING - INTERMEDIATE Not ready for Inspection incomplete