Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - INTERMEDIATE
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/29/2019 | PLUMBING - INTERMEDIATE | Approved | ||
| 12/20/2018 | PLUMBING - INTERMEDIATE | Denied | 1- Shallprovide a directional fitting for the tub waste line. 2- Fernco couplings are not approved within the structure, shall provide mission specialty couplings. 3- Shall provide a directional fitting for the laundry waste line. 4- Shall provide cast iron perm. caps for all dead end drains under the slab. 5- Threaded fittings not allowed in a concealed location at lavatory waste line. 6- 2 inch waste line can not be reduced to 11/2 inch existing waste line in wall. 7- Clothes washer stand pipe distance is 18 inches minimum and 42 inches maximum. 8- Shall provide a minimum of 18 inches if copper piping then tranation to pex at the water heater supplies. 9- Shall provide a directional fitting for the water closet and install in a conventional manner. 10- Shall provide tracer wire on bldg. Sewer. 11- Horizontal branch vent for the front bathroom lavatory shall be located a minimum of 6 inches above the flood level rim of the fixture. 12- Front bathroom tub requires a trap and vent. 13- Kitchen sink horizontal vent shall be located 6 inches above the flood level rim of the fixture. |
|
| 12/12/2018 | PLUMBING - INTERMEDIATE | Not ready for Inspection | incomplete |