Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ADDITION
Address NEW:
317 W 23RD ST BLDG #5
Apply Date:
06/06/2018
Applicant:
VINT, ROBERT WALTER
Description:
CHURCH
Contractors:
  • BARKER CONTRACTING INC **APA**

Permit Reviews

Permit Number - T18CM04412
Permit Status: C of o
Permit Description: CHURCH
Start Date Submittal Complete Date Status  
01/08/2019 3RD PARTY REVIEW - REVISION/OTHER 01/15/2019 COMPLETED Review Details
06/04/2019 3RD PARTY REVIEW - REVISION/OTHER 06/04/2019 COMPLETED Review Details
06/04/2019 POST 3RD PARTY REVIEW 06/04/2019 COMPLETED Review Details
06/06/2018 PLANS OK TO SUBMIT - COMM 06/06/2018 COMPLETED Review Details
06/08/2018 3RD PARTY REVIEW - COMMERCIAL 09/04/2018 COMPLETED Review Details
09/04/2018 POST 3RD PARTY REVIEW 12/06/2018 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T18CM04412
Permit Status: C of o
Permit Description: CHURCH
Total Outstanding Activity Conditions - 1
Date Name
06/06/2018 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T18CM04412
Permit Description: CHURCH
Total Completed Inspections - 45
Date Description Inspector Results Comments
10/24/2018 PLUMBING - ABOVE CEILING MRAMBER Approved Phase 1 ok
10/24/2018 PLUMBING - INTERMEDIATE MRAMBER Approved Phase 1 ok
10/24/2018 PLUMBING - ROUGH, SOIL MRAMBER Approved Phase 1 ok
11/02/2018 ELECTRIC - INTERMEDIATE BJONES Approved Underground PVC conduit including2-2” futures for solar panels INSPECTION WAS CHANGED FROM AP TO PA TO ALLOW FOR INSPECTIONS ON ADDITIONAL BUILDINGS
11/09/2018 SHEET ROCK NAILING RCHANDLER Approved Building 5
11/09/2018 FRAMING RCHANDLER Approved Building 5
11/27/2018 EXCAVATION/LAYOUT REBAR & ZON DMCCARTHY Approved changed from AP to PA per MHASSAN
11/27/2018 ELECTRIC - CABLE DROP DMCCARTHY Approved
11/30/2018 ELECTRIC - UNDERGROUND MHASSAN Approved okay from Transformer to breaker box at Head Start
12/05/2018 REINFORCED MASONRY PRE-GROUT DMCCARTHY Approved Vertical rebar hollow to bottom for grout in bedded rebar at 32 inches on center add rebar were not on 32 inches on center watched go do it.
12/11/2018 BUILDING PRE-SLAB DMCCARTHY Approved building pre-slab trash enclosure
The building that will be constructed will also have building pre-slab inspections therefore this is a partial for the parking area trash enclosure
01/29/2019 ELECTRIC - SERVICE RELOCATION BSTEVENS Approved APPROVAL TO RE SEND CLEARANCE TO TEP FOR RECN
01/29/2019 TEP CLEARANCE - AM DMCCARTHY Approved INCR
BLDG#5
03/27/2019 STEM WALL/RETAINING WALL RCAMACHO Approved Top out 1020
04/11/2019 ELECTRIC - UFER MHASSAN Approved
05/30/2019 PLUMBING - GAS PRESSURE TEST TVALENCIA Approved
06/18/2019 STUCCO MESH MHASSAN Approved
06/18/2019 ROOF NAILING MHASSAN Approved
07/16/2019 MECHANICAL - INTERMEDIATE MHASSAN Approved
07/16/2019 U VALUE FOR WINDOW MHASSAN Approved
08/23/2019 SITE - SEWER TVALENCIA Approved
09/13/2019 ENGINEERING - FINAL BBENEDON Approved
11/13/2019 MECHANICAL - ABOVE CEILING JBURGE Approved
11/13/2019 MECHANICAL - HOODS JBURGE Approved
11/13/2019 MECHANICAL - HOOD SYSTEMS JBURGE Approved
11/13/2019 PLUMBING - PRE SLAB JBURGE Approved
11/13/2019 PLUMBING - GAS PRESS TEST FNL JBURGE Approved
11/13/2019 PLUMBING - FINAL JBURGE Approved
11/18/2019 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved
11/18/2019 BUILDING ABOVE CEILING JBURGE Approved
11/18/2019 ELECTRIC - ABOVE CEILING JBURGE Approved
11/18/2019 ELECTRIC - OUTDOOR LIGHTING JBURGE Approved
11/18/2019 OUTDOOR LIGHTING FINAL JBURGE Approved
11/18/2019 ELECTRIC - FINAL JBURGE Approved
11/19/2019 FIRE - FINAL CBASALDUA Approved
11/19/2019 FIRE - KITCHEN EXH HOOD FINAL CBASALDUA Approved
11/19/2019 FIRE - ALARM FINAL CBASALDUA Approved
11/19/2019 FIRE SPKLR - FINAL CBASALDUA Approved
11/19/2019 NPPO - FINAL BBENEDON Approved Will inspect landscaping under DP permit when ready.
11/19/2019 SIGN - FINAL BBENEDON Approved Will inspect landscaping under DP permit when ready.
11/19/2019 LANDSCAPE - FINAL BBENEDON Approved Will inspect landscaping under DP permit when ready.
11/20/2019 RIGHT OF WAY - FINAL Bravin Approved all permit work has met requirements. No issues
12/03/2019 BUILDING - FINAL ESTEVENS Approved AWAITING FINAL AIR BALANCE REPORT
12/03/2019 MECHANICAL - FINAL RSHERRY Approved AIR BALANCE REPORT INCOMPLETE
12/03/2019 MECHANICAL - FINAL DMCCARTHY Approved Pres church Reno sup ire

Documents

File Name Document Type  
T18CM04412 TEMP CERT OF OCC.PDF CERT OF OCC VIEW
T18CM04412 TCO.PDF CERT OF OCC VIEW
T18CM04412 COFO.PDF CERT OF OCC VIEW
001_A0.0.TIF CONSTRPLANS VIEW
002_1 OF 13.TIF CONSTRPLANS VIEW
003_2 OF 13.TIF CONSTRPLANS VIEW
004_3 OF 13.TIF CONSTRPLANS VIEW
005_4 OF 13.TIF CONSTRPLANS VIEW
006_5 OF 13.TIF CONSTRPLANS VIEW
007_6 OF 13.TIF CONSTRPLANS VIEW
008_7 OF 12.TIF CONSTRPLANS VIEW
009_8 OF 13.TIF CONSTRPLANS VIEW
010_9 OF 13.TIF CONSTRPLANS VIEW
011_10 OF 13.TIF CONSTRPLANS VIEW
012_11 OF 13.TIF CONSTRPLANS VIEW
013_12 OF 13.TIF CONSTRPLANS VIEW
014_13 OF 13.TIF CONSTRPLANS VIEW
015_A0.1.TIF CONSTRPLANS VIEW
016_A1.1.TIF CONSTRPLANS VIEW
017_A1.2.TIF CONSTRPLANS VIEW
018_A1.2A.TIF CONSTRPLANS VIEW
019_A1.2B.TIF CONSTRPLANS VIEW
020_A1.3.TIF CONSTRPLANS VIEW
021_A1.4.TIF CONSTRPLANS VIEW
022_A1.5.TIF CONSTRPLANS VIEW
023_A1.6.TIF CONSTRPLANS VIEW
024_A2.1.TIF CONSTRPLANS VIEW
025_A2.2.TIF CONSTRPLANS VIEW
026_A2.3.TIF CONSTRPLANS VIEW
027_A3.1.TIF CONSTRPLANS VIEW
028_A3.2.TIF CONSTRPLANS VIEW
029_A3.3.TIF CONSTRPLANS VIEW
030_A4.1.TIF CONSTRPLANS VIEW
031_A4.2.TIF CONSTRPLANS VIEW
032_A5.1.TIF CONSTRPLANS VIEW
033_A5.2.TIF CONSTRPLANS VIEW
034_A6.1.TIF CONSTRPLANS VIEW
035_S1.0.TIF CONSTRPLANS VIEW
036_S2.0.TIF CONSTRPLANS VIEW
037_S2.1.TIF CONSTRPLANS VIEW
038_S3.0.TIF CONSTRPLANS VIEW
039_MP1.1.TIF CONSTRPLANS VIEW
040_MD1.1.TIF CONSTRPLANS VIEW
041_M1.1.TIF CONSTRPLANS VIEW
042_M2.1.TIF CONSTRPLANS VIEW
043_M2.2.TIF CONSTRPLANS VIEW
044_M3.1.TIF CONSTRPLANS VIEW
045_PD1.1.TIF CONSTRPLANS VIEW
046_P1.1.TIF CONSTRPLANS VIEW
047_P2.1.TIF CONSTRPLANS VIEW
048_P3.1.TIF CONSTRPLANS VIEW
049_P3.2.TIF CONSTRPLANS VIEW
050_P3.3.TIF CONSTRPLANS VIEW
051_E1.0.TIF CONSTRPLANS VIEW
052_E1.1.TIF CONSTRPLANS VIEW
053_E1.2.TIF CONSTRPLANS VIEW
054_E1.3.TIF CONSTRPLANS VIEW
055_E2.0.TIF CONSTRPLANS VIEW
056_E2.1.TIF CONSTRPLANS VIEW
057_E2.2.TIF CONSTRPLANS VIEW
058_E3.0.TIF CONSTRPLANS VIEW
002_SHEET 1 OF 1.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW
T18CM04412 AIR BALANCE.PDF DOCUMENTS VIEW
T18CM04412 TAB REVIEW 2.PDF DOCUMENTS VIEW