Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
COMMERCIAL ALTERATION
Address:
4949 N ORACLE RD
Apply Date:
03/26/2018
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
TI: RESTAURANT
Architects:
  • LOOKER, JEFF ANTHONY
Contractors:
  • EQUITEAM LLC

Permit Reviews

Permit Number - T18CM02240
Permit Status: Expired
Permit Description: TI: RESTAURANT
Start Date Submittal Complete Date Status  
03/26/2018 PLANS OK TO SUBMIT - COMM 03/28/2018 COMPLETED Review Details
03/29/2018 3RD PARTY REVIEW - COMMERCIAL TI 04/05/2018 COMPLETED Review Details
04/04/2018 COMMERCIAL - TI 06/06/2018 COMPLETED Review Details
06/06/2018 RESUBMITTAL 07/19/2018 COMPLETED Review Details
07/26/2018 REVISION - - 1ST 07/31/2018 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T18CM02240
Permit Status: Expired
Permit Description: TI: RESTAURANT
Total Outstanding Activity Conditions - 3
Date Name
03/26/2018 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
08/29/2018 SPECIAL INSPECTION FORMS AND REPORTS REQUIRED PRIOR TO ISSUANCE OF A CERTIFICATE OF OCCUPANCY.
08/29/2018 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.

Completed Inspections

Permit Status: Expired
Permit Number: T18CM02240
Permit Description: TI: RESTAURANT
Total Completed Inspections - 26
Date Description Inspector Results Comments
09/18/2018 SITE - SEWER DFLORES2 Approved IVRS - Inspection :*
10/04/2018 MECHANICAL - INTERMEDIATE JBURGE Approved
10/04/2018 PLUMBING - GAS PRESSURE TEST JBURGE Approved Line tested at 15 psi.
10/04/2018 PLUMBING - INTERMEDIATE JBURGE Approved
10/04/2018 ELECTRIC - INTERMEDIATE JBURGE Approved
10/04/2018 ROOF NAILING JBURGE Approved Dens-deck system. 3 part roofing system
10/11/2018 FRAMING DQUINN Approved
10/18/2018 ELECTRIC - OUTDOOR LIGHTING JBURGE Approved canned lights under canopy. Ok to cover progress areas
10/30/2018 PLUMBING - ROUGH, SOIL JBURGE Approved
10/30/2018 ELECTRIC - UNDERGROUND JBURGE Approved Ok to cover progress areas.
10/30/2018 EXT METAL CLIPS/EXT SHEATHING JBURGE Approved
11/05/2018 BUILDING ABOVE CEILING DMCCARTHY Approved
11/14/2018 PLUMBING - FINAL JBURGE Approved chlorination test completed. Gas meter reconnect called in to S W Gas at 1340 hours.
11/14/2018 ELECTRIC - PROGRESS JBURGE Approved
11/14/2018 STUCCO MESH JBURGE Approved
11/15/2018 GAS CLEARANCE JBURGE Approved
11/16/2018 ELECTRIC - ABOVE CEILING TVALENCIA Approved
11/20/2018 OUTDOOR LIGHTING FINAL JBURGE Approved
11/20/2018 ELECTRIC - FINAL JBURGE Approved
12/03/2018 FIRE - KITCHEN EXH HOOD FINAL jvincent Approved
12/04/2018 FIRE - FINAL jvincent Approved
12/06/2018 PLUMBING - ABOVE CEILING JBURGE Approved approved due to 3090 approval from James
12/06/2018 MECHANICAL - FINAL JBURGE Approved
12/06/2018 MECHANICAL - ABOVE CEILING JBURGE Approved
12/06/2018 BUILDING - FINAL JBURGE Approved
12/07/2018 ENGINEERING - FINAL BBENEDON Approved

Documents

File Name Document Type  
001_TS1.0.TIF CONSTRPLANS VIEW
002_TS1.1.TIF CONSTRPLANS VIEW
003_TS1.2.TIF CONSTRPLANS VIEW
004_SD1.0.TIF CONSTRPLANS VIEW
005_SD2.0.TIF CONSTRPLANS VIEW
006_SD2.1.TIF CONSTRPLANS VIEW
007_SD2.2.TIF CONSTRPLANS VIEW
008_A0.1.TIF CONSTRPLANS VIEW
009_A1.0.TIF CONSTRPLANS VIEW
010_A1.1.TIF CONSTRPLANS VIEW
011_A2.0.TIF CONSTRPLANS VIEW
012_A3.0.TIF CONSTRPLANS VIEW
013_A4.0.TIF CONSTRPLANS VIEW
014_A4.1.TIF CONSTRPLANS VIEW
015_A6.0.TIF CONSTRPLANS VIEW
016_A6.1.TIF CONSTRPLANS VIEW
017_A7.0.TIF CONSTRPLANS VIEW
018_A8.0.TIF CONSTRPLANS VIEW
019_A9.0.TIF CONSTRPLANS VIEW
020_A9.1.TIF CONSTRPLANS VIEW
021_A9.2.TIF CONSTRPLANS VIEW
022_ID1.0.TIF CONSTRPLANS VIEW
023_ID1.1.TIF CONSTRPLANS VIEW
024_ID2.0.TIF CONSTRPLANS VIEW
025_ID3.1.TIF CONSTRPLANS VIEW
026_ID4.0.TIF CONSTRPLANS VIEW
027_ID4.1.TIF CONSTRPLANS VIEW
028_ID4.2.TIF CONSTRPLANS VIEW
029_S0.1.TIF CONSTRPLANS VIEW
030_S2.1.TIF CONSTRPLANS VIEW
031_S3.1.TIF CONSTRPLANS VIEW
032_S3.2.TIF CONSTRPLANS VIEW
033_MP0.1.TIF CONSTRPLANS VIEW
034_MP0.2.TIF CONSTRPLANS VIEW
035_M2.1.TIF CONSTRPLANS VIEW
036_M2.2.TIF CONSTRPLANS VIEW
037_M8.1.TIF CONSTRPLANS VIEW
038_P2.1.TIF CONSTRPLANS VIEW
039_P2.2.TIF CONSTRPLANS VIEW
040_P2.3.TIF CONSTRPLANS VIEW
041_P8.1.TIF CONSTRPLANS VIEW
001_E0.1.TIF CONSTRPLANS VIEW
042_E1.0.TIF CONSTRPLANS VIEW
002_E2.0.TIF CONSTRPLANS VIEW
043_E2.1.TIF CONSTRPLANS VIEW
003_E3.0.TIF CONSTRPLANS VIEW
044_E3.1.TIF CONSTRPLANS VIEW
045_E3.2.TIF CONSTRPLANS VIEW
046_E4.1.TIF CONSTRPLANS VIEW
047_E6.1.TIF CONSTRPLANS VIEW
048_ES1.2.TIF CONSTRPLANS VIEW
049_ES1.3.TIF CONSTRPLANS VIEW
050_SP1.0.TIF CONSTRPLANS VIEW
051_SP1.1.TIF CONSTRPLANS VIEW
052_SP1.2.TIF CONSTRPLANS VIEW
053_SP1.3.TIF CONSTRPLANS VIEW
054_SP2.0.TIF CONSTRPLANS VIEW
055_SP3.0.TIF CONSTRPLANS VIEW
056_SP4.0.TIF CONSTRPLANS VIEW
057_SP5.0.TIF CONSTRPLANS VIEW
058_SP6.0.TIF CONSTRPLANS VIEW
059_SP6.1.TIF CONSTRPLANS VIEW
060_SP6.2.TIF CONSTRPLANS VIEW
061_SP6.3.TIF CONSTRPLANS VIEW
062_SA1.0.TIF CONSTRPLANS VIEW
063_SA1.1.TIF CONSTRPLANS VIEW
064_SA2.0.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW