Permit: T17CM05323
Permit Details
Apply Date:
07/11/2017
Applicant:
WILLIAMSONS HEATING AND COOLING INC ** APA **
Description:
SPLIT SYSTEM/ REPLACE WATER HEATER
Contractors:
- WILLIAMSONS HEATING AND COOLING INC ** APA **
Permit Reviews
Permit Number - T17CM05323
Permit Status: Expired
Permit Description: SPLIT SYSTEM/ REPLACE WATER HEATER
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
07/11/2017 | WALK THRU - RES | 07/12/2017 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T17CM05323
Permit Status: Expired
Permit Description: SPLIT SYSTEM/ REPLACE WATER HEATER
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
07/11/2017 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T17CM05323
Permite Description: SPLIT SYSTEM/ REPLACE WATER HEATER
Total Outstanding Inspections - 1
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/22/2017 | MECHANICAL - FINAL | N/A | Denied | COLD WATER PVC AND COPPER FLEX NOT ALLOWED ON T&P DRAIN. REMOVE THE SHIM FROM BEHIND WATER HEATER AND PROPERLY SUPPORT WATER HEATER. TIGHTEN ROMEX CONNECTOR ONTO CORDS AT FURNACE. PROVIDE TAMPER PROOF CAPS AT CONDENSOR. #8 WIRE REQUIRED FOR 40 AMP AT CONDENSOR. |