Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
SINGLE FAMILY NEW
Address:
3309 E SENECA ST
Address NEW:
3309 E SENECA ST
Apply Date:
05/03/2017
Applicant:
COZZETTI COMPANY INC , THE
Description:
NEW SFR
Contractors:
  • COZZETTI COMPANY INC , THE

Permit Reviews

Permit Number - T17CM03451
Permit Status: C of o
Permit Description: NEW SFR
Start Date Submittal Complete Date Status  
05/03/2017 RESIDENTIAL - BLDG/ZONING-WALKTHRU 05/25/2017 COMPLETED Review Details
05/25/2017 RESIDENTIAL - BLDG/WWM 06/26/2017 COMPLETED Review Details
06/26/2017 RESUBMITTAL 07/12/2017 COMPLETED Review Details
09/08/2017 REVISION - - 1ST 09/08/2017 COMPLETED Review Details
10/19/2017 REVISION - - 2ND 12/04/2017 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T17CM03451
Permit Status: C of o
Permit Description: NEW SFR
Total Outstanding Activity Conditions - 1
Date Name
05/03/2017 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T17CM03451
Permit Description: NEW SFR
Total Completed Inspections - 23
Date Description Inspector Results Comments
07/21/2017 EXCAVATION/LAYOUT REBAR & ZON JMILITE1 Approved OK TO POUR 32 COLUMN CAISONS.
07/26/2017 ELECTRIC - UNDERGROUND BSTEVENS Approved
07/27/2017 PLUMBING - ROUGH, SOIL JMILITE1 Approved OK TO BACKFILL DWV AND WATER LINE.
07/27/2017 PLUMBING - YARD WTR LINE/TEST JMILITE1 Approved OK TO BACKFILL DWV AND WATER LINE.
08/17/2017 ELECTRIC - SERVICE UPGRADE JMILITE1 Approved OK RES. ECO
09/20/2017 U VALUE FOR WINDOW TVALENC1 Approved IVRS - Inspection :*
09/20/2017 FRAMING TVALENC1 Approved IVRS - Inspection :*
09/20/2017 EXT METAL CLIPS/EXT SHEATHING TVALENC1 Approved IVRS - Inspection :*
09/28/2017 MECHANICAL - INTERMEDIATE JMILITE1 Approved IVRS - Inspection :*
09/28/2017 ELECTRIC - INTERMEDIATE JMILITE1 Approved IVRS - Inspection :*
10/04/2017 ELECTRIC - UFER JMILITE1 Approved IVRS - Inspection :*
10/04/2017 ROOF NAILING JMILITE1 Approved IVRS - Inspection :*
10/05/2017 TEP CLEARANCE - AM JMILITELLO Approved ECO
10/05/2017 ELECTRIC - TEMPORARY SERVICE JMILITE1 Approved OK RES. ECO
OK TO INSULATE.
WATER LINES OK TO COVER.
10/23/2017 PLUMBING - GAS PRESSURE TEST NORTH Approved
10/23/2017 PLUMBING - INTERMEDIATE NORTH Approved
10/23/2017 SHEET ROCK NAILING NORTH Approved
12/14/2017 MECHANICAL - FINAL BSTEVENS Approved
12/14/2017 PLUMBING - FINAL BSTEVENS Approved
12/14/2017 OUTDOOR LIGHTING FINAL BSTEVENS Approved
12/14/2017 ELECTRIC - FINAL BSTEVENS Approved
12/14/2017 BUILDING - FINAL BSTEVENS Approved
12/14/2017 PLUMBING - PRE SLAB aquiroz Approved

Documents

File Name Document Type  
None CERT OF OCC VIEW
001_A1.TIF CONSTRPLANS VIEW
002_A2.TIF CONSTRPLANS VIEW
003_A3.TIF CONSTRPLANS VIEW
004_A4.TIF CONSTRPLANS VIEW
005_A5.TIF CONSTRPLANS VIEW
006_A6.TIF CONSTRPLANS VIEW
007_A7.TIF CONSTRPLANS VIEW
008_A8.TIF CONSTRPLANS VIEW
009_A9.TIF CONSTRPLANS VIEW
010_E1.TIF CONSTRPLANS VIEW
011_M1.TIF CONSTRPLANS VIEW
012_S1.TIF CONSTRPLANS VIEW
013_S2.TIF CONSTRPLANS VIEW
014_S3.TIF CONSTRPLANS VIEW
015_S4.TIF CONSTRPLANS VIEW
016_S5.TIF CONSTRPLANS VIEW
001_D1.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW
TRUSSES.PDF DOCUMENTS VIEW
REPORT.PDF DOCUMENTS VIEW
None DOCUMENTS VIEW