Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Permit Details

Status:
Complete
Type:
Residential Building - One or Two Family
Address NEW:
2712 W MONTE VISTA PL
Apply Date:
04/13/2017
Applicant:
Dan Martin
Description:
SFR

Permit Reviews

Permit Number - T17CM02882
Permit Status: Complete
Permit Description: SFR
Start Date Submittal Complete Date Status  
04/13/2017 PLANS OK TO SUBMIT - RES 04/14/2017 COMPLETED Review Details
04/14/2017 RESIDENTIAL - BLDG/ZONING/ENGINE/WWM 05/12/2017 COMPLETED Review Details
05/15/2017 RESUBMITTAL 05/15/2017 COMPLETED Review Details
05/15/2017 RESUBMITTAL 05/23/2017 COMPLETED Review Details
09/11/2018 REVISION - - 1ST 09/11/2018 COMPLETED Review Details
04/15/2024 BUILDING DEFERRED SUBMITTAL REVIEW v.1 04/17/2024 APPROVED Review Details

Conditions

Permit Number - T17CM02882
Permit Status: Complete
Permit Description: SFR
Date Description Comments
04/13/2017 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.
03/14/2024 SPECIAL INSPECTION FOR FIELD WELDING IS REQUIRED.
03/14/2024 Separate submittal to PC RWRD is required for new connections to sewer, new water meters and upsized water meters. Contact sewer@pima.gov for review and assessment.

Outstanding Inspections

Permit Status: Complete
Permit Number: T17CM02882
Permite Description: SFR
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
10/27/2022 RSBU - Building Final N/A Not Ready
04/03/2023 COT - RSEL - Electrical Final N/A Canceled Canceled per home owner. 4/3/2023

Completed Inspections

Permit Status: Complete
Permit Number: T17CM02882
Permit Description: SFR
Total Completed Inspections - 23
Date Description Inspector Results Comments
08/10/2017 COT - RSBU - Stem Wall/Retaining Wall Passed {Activity date: 08/10/2017; Status: Approved; Inspector: JBURGE; Comment: Entered by JBURGE1 - } ; {Activity date: 08/02/2017; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by JBURGE1 - GROUT SOLID STEM WALLS: #5 REBAR/BOLTS, "J" BOLTS AT 48" O.C.}
08/10/2017 COT - RSBU - Masonry Pregrout Passed {Activity date: 08/10/2017; Status: Approved; Inspector: JBURGE; Comment: Entered by JBURGE1 - } ; {Activity date: 08/02/2017; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by JBURGE1 - TYPICAL WALLS AT 32" - 48"; #4 REBAR AT 16" O.C.. OK TO GROUT PROGRESS AREAS.}
09/07/2018 COT - RSBU - Sustainability Passed {Activity date: 09/07/2018; Status: Approved; Inspector: ESTEVENS; Comment: Entered by CMURPHY1 - }
01/11/2019 COT - RSPL - Gas Pressure Test Passed {Activity date: 01/11/2019; Status: Approved; Inspector: DMCCARTHY; Comment: Entered by CBELL1 - 15 psi for 10 minutes
}
01/18/2019 COT - RSPL - Rough Soil Passed {Activity date: 01/18/2019; Status: Approved; Inspector: DMCCARTHY; Comment: Entered by CBELL1 - No leaks observed
Green tracer wire from back of house towards HCS, underground plumbing in front is under slab in the garage future} ; {Activity date: 01/11/2019; Status: Denied; Inspector: DMCCARTHY; Comment: Entered by CBELL1 - water leaking at elbow closest to street. AND no green tracer wire over 4 inch sewer pipe in yard.}
05/17/2019 COT - RSBU - Preslab Passed {Activity date: 05/17/2019; Status: Approved; Inspector: TVALENCIA; Comment: Entered by CBELL1 - } ; {Activity date: 05/14/2019; Status: Denied; Inspector: TVALENCIA; Comment: Entered by CBELL1 - 1- Shall complete forms for footing and slab.
2- Reference footing detail 1 S-1 showing the top rebar.
3- Shall wrap plumbing risers and any plumbing in concrete.
4- 20 feet of copper Ufer has been provided.}
02/03/2020 COT - RSEL - Grounding/Bonding Passed {Activity date: 02/03/2020; Status: Approved; Inspector: DQUINN; Comment: Entered by DMERANZ1 - } ; {Activity date: 01/30/2020; Status: Denied; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - 1- Shall provide 18 inches of cover from top of conduit piping to finish grade.
Reference Table E3803.1 2012 IRC} ; {Activity date: 05/17/2019; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by CBELL1 - 1- 20 feet of copper #4 Ufer conductor provided in footing.} ; {Activity date: 05/14/2019; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by CBELL1 - 1- Shall complete forms for footing and slab.
2- Reference footing detail 1 S-1 showing the top rebar.
3- Shall wrap plumbing risers and any plumbing in concrete.
4- 20 feet of copper Ufer has been provided.}
01/05/2021 COT - RSBU - Roof Nailing Passed {Activity date: 01/05/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VLEON1 - APPROVED} ; {Activity date: 07/13/2020; Status: Denied; Inspector: ESTEVENS; Comment: Entered by JSCHNEI2 - Denied. No contact number or name in Messages, no contractor listed. Please call your inspector for further information.} ; {Activity date: 05/16/2018; Status: Partial Approval; Inspector: BBENEDO1; Comment: Entered by BBENEDO1 - IVRS - Inspection :*}
01/05/2021 COT - LCBU - Framing Passed {Activity date: 01/05/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by VLEON1 - APPROVED} ; {Activity date: 07/13/2020; Status: Denied; Inspector: ESTEVENS; Comment: Entered by JSCHNEI2 - Denied. No contact number or name in Messages, no contractor listed. Please call your inspector for further information.} ; {Activity date: 09/07/2018; Status: Partial Approval; Inspector: ESTEVENS; Comment: Entered by CMURPHY1 - submit revised plans to the city.
} ; {Activity date: 02/05/2018; Status: Partial Approval; Inspector: BSTEVENS; Comment: Entered by BSTEVENS - 1. PROVIDE APPROVED ENGINEERING FOR CHANGE IN ROOF FRAMING.
2. GENERAL FRAMING LOOK GOOD, RE-CALL WHEN WALL BRACING IS COMPLETED.}
02/09/2021 COT - LCPL - Plumbing Intermediate Passed {Activity date: 02/09/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by ESTEVEN1 - }
02/09/2021 COT - RSBU - Exterior/Interior Clips/Sheathing/Framing Passed {Activity date: 02/09/2021; Status: Approved; Inspector: ESTEVENS; Comment: Entered by ESTEVEN1 - }
02/18/2021 COT - BULD - SWG Clearance Passed {Activity date: 02/18/2021; Status: Approved; Inspector: BSTEVENS; Comment: Entered by BSTEVENS - }
11/12/2021 COT - RSME - Mechanical Final Passed {Activity date: 11/12/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap

Close permit}
11/12/2021 RSME - Mechanical Progress Passed {Activity date: 11/12/2021; Status: Approved; Inspector: DQUINN; Comment: Entered by NGARCIA3 - Ap}
05/10/2022 COT - RSPL - Yard Water Line Passed {Activity date: 05/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
05/10/2022 COT - RSEL - Electrical Underground Passed {Activity date: 05/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 01/30/2020; Status: Denied; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - 1- Shall provide 18 inches of cover from top of conduit piping to finish grade.
Reference Table E3803.1 2012 IRC}
05/10/2022 COT - RSPL - Sewer Passed {Activity date: 05/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
05/10/2022 COT - RSEL - Construction Power Passed {Activity date: 05/10/2022; Status: Not Applicable; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Not Applicable.} ; {Activity date: 05/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved}
05/10/2022 RSEL - Electrical Progress Passed {Activity date: 05/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 02/03/2020; Status: Not ready for Inspection; Inspector: DQUINN; Comment: Entered by DMERANZ1 - Leave message with contact phone # for inspectors questions.
} ; {Activity date: 01/30/2020; Status: Denied; Inspector: TVALENCIA; Comment: Entered by DMERANZ1 - 1- Shall provide 18 inches of cover from top of conduit piping to finish grade.
Reference Table E3803.1 2012 IRC}
05/10/2022 COT - RSBU - Excavation/Rebar/Zoning Passed {Activity date: 05/10/2022; Status: Approved; Inspector: DMUNIZ; Comment: Entered by NGARCIA3 - Approved} ; {Activity date: 05/17/2019; Status: Partial Approval; Inspector: TVALENCIA; Comment: Entered by CBELL1 - 1- Steel reinforcement provided for the garage slab.} ; {Activity date: 08/08/2017; Status: Partial Approval; Inspector: JBURGE; Comment: Entered by JBURGE1 - COLUMN FOOTING #7; ENSURE DOUBLE #3 TIES AT THE TOP AND #3 RINGS AT 12" APART - DETAIL #2, PAGE S1.0. OK TO PLACE CONCRETE.} ; {Activity date: 07/24/2017; Status: Partial Approval; Inspector: ESTEVEN1; Comment: Entered by ESTEVEN1 - OK TO POUR, EXCEPT F7 POST FOOTING} ; {Activity date: 07/19/2017; Status: Denied; Inspector: ESTEVEN1; Comment: Entered by ESTEVEN1 - REBAR ISCORRECT, NEEDS TO BE 3" FROM THE EARTH} ; {Activity date: 07/17/2017; Status: Cancelled; Inspector: NORTH; Comment: Entered by BNORTH1 - }
09/18/2023 COT - RSPL - Plumbing Final Passed
03/13/2024 RSBU - Building Final Passed
03/13/2024 COT - RSEL - Electrical Final Passed