Inspection History Details
Inspection Status: Passed
Inspection History: COT - RSEL - Grounding/Bonding
Permit Number - T17CM02882
Inspection Description - COT - RSEL - Grounding/Bonding
Inspection Status - Passed
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/03/2020 | COT - RSEL - Grounding/Bonding | DQUINN | Approved | Entered by DMERANZ1 - |
| 01/30/2020 | COT - RSEL - Grounding/Bonding | TVALENCIA | Denied | Entered by DMERANZ1 - 1- Shall provide 18 inches of cover from top of conduit piping to finish grade. Reference Table E3803.1 2012 IRC |
| 05/17/2019 | COT - RSEL - Grounding/Bonding | TVALENCIA | Partial Approval | Entered by CBELL1 - 1- 20 feet of copper #4 Ufer conductor provided in footing. |
| 05/14/2019 | COT - RSEL - Grounding/Bonding | TVALENCIA | Partial Approval | Entered by CBELL1 - 1- Shall complete forms for footing and slab. 2- Reference footing detail 1 S-1 showing the top rebar. 3- Shall wrap plumbing risers and any plumbing in concrete. 4- 20 feet of copper Ufer has been provided. |