Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T16CM09274
Permit Details
Apply Date:
12/12/2016
Applicant:
RAMIREZ IRMA
Description:
UPGRADE UP TO 200AMP & REPL GAS LINE
Permit Reviews
Permit Number - T16CM09274
Permit Status: Final
Permit Description: UPGRADE UP TO 200AMP & REPL GAS LINE
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
12/12/2016 | WALK THRU - RES | 12/12/2016 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T16CM09274
Permit Status: Final
Permit Description: UPGRADE UP TO 200AMP & REPL GAS LINE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
12/12/2016 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T16CM09274
Permit Description: UPGRADE UP TO 200AMP & REPL GAS LINE
Total Completed Inspections - 6
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/21/2016 | ELECTRIC - SERVICE UPGRADE | RCAMACHO | Approved | UNABLE TO LEAVE MESSAGE MAILBOX FULL PROVIDE PROOF OF GROUND CLAMPS OK FOR DIRECT BURIAL OR USE ACORN CLAMPS |
12/23/2016 | PLUMBING - GAS PRESSURE TEST | mramber1 | Approved | 1-all underground fittings are to be coated per IPC, 20 mil. with adhesive 2-all tool marks to be coated 3-black pipe to be 6" above grade 4-pipe to be min. 12" below grade 5-provide approved bond clamp 6-water heater flue not properly terminated |
02/21/2017 | TEP CLEARANCE - AM | CAMACHO | Approved | INCR |
02/22/2017 | PLUMBING - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
02/24/2017 | GAS CLEARANCE | MRAMBER | Approved | |
04/03/2017 | ELECTRIC - FINAL | RCAMACHO | Approved |