Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
09/07/2016
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
OFFICE
Architects:
  • EGLIN, EVAN SAR
Contractors:
  • VENTURE WEST CONSTRUCTION L L C

Permit Reviews

Permit Number - T16CM06871
Permit Status: C of o
Permit Description: OFFICE
Start Date Submittal Complete Date Status  
09/07/2016 COMMERCIAL - TI 09/16/2016 COMPLETED Review Details
09/16/2016 RESUBMITTAL - TI ALL 09/29/2016 COMPLETED Review Details
09/29/2016 COMMERCIAL - TI 10/25/2016 COMPLETED Review Details
10/26/2016 REVISION - - 1ST 11/02/2016 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T16CM06871
Permit Status: C of o
Permit Description: OFFICE
Total Outstanding Activity Conditions - 1
Date Name
09/07/2016 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T16CM06871
Permit Description: OFFICE
Total Completed Inspections - 19
Date Description Inspector Results Comments
11/10/2016 PLUMBING - ROUGH, SOIL TVALENC1 Approved IVRS - Inspection :*
12/02/2016 SHEET ROCK NAILING TVALENC1 Approved
12/23/2016 PLUMBING - INTERMEDIATE JMILITE1 Approved
12/23/2016 ELECTRIC - INTERMEDIATE JMILITE1 Approved OK TO CLOSE WALLS AND CEILING.
12/29/2016 MECHANICAL - ABOVE CEILING TVALENC1 Approved
12/29/2016 PLUMBING - ABOVE CEILING TVALENC1 Approved
12/29/2016 ELECTRIC - ABOVE CEILING TVALENC1 Approved
12/30/2016 MECHANICAL - INTERMEDIATE TVALENC1 Approved
12/30/2016 FRAMING TVALENC1 Approved
12/30/2016 BUILDING ABOVE CEILING TVALENC1 Approved
12/30/2016 CERTIFICATE OF OCCUPANCY TVALENC1 Approved
12/30/2016 MECHANICAL - FINAL TVALENC1 Approved
12/30/2016 BUILDING - FINAL TVALENC1 Approved
12/30/2016 PLUMBING - FINAL TVALENC1 Approved
12/30/2016 PLUMBING - PROGRESS TVALENC1 Approved
12/30/2016 ELECTRIC - FINAL TVALENC1 Approved
12/30/2016 ENGINEERING - FINAL RLEDONNE Approved
12/30/2016 FIRE - FINAL jvincent Approved
12/30/2016 FIRE - FINAL jvincent Approved Need the following:
1) Remove exit signs x 2. Currently both have open faces with exposed electrical. Exit signs not required.
2) Patch drywall in "mechanical" room. Ceiling and wall.
3) Repair exit sign in receptionist office or remove.
will mount the 2 extinguishers.

Documents

File Name Document Type  
None CERT OF OCC VIEW
001_TS1.TIF CONSTRPLANS VIEW
002_D1.TIF CONSTRPLANS VIEW
003_D1.1.TIF CONSTRPLANS VIEW
004_A1.TIF CONSTRPLANS VIEW
005_A2.TIF CONSTRPLANS VIEW
006_A3.TIF CONSTRPLANS VIEW
007_SP1.TIF CONSTRPLANS VIEW
008_SP2.TIF CONSTRPLANS VIEW
009_M1.TIF CONSTRPLANS VIEW
010_M2.TIF CONSTRPLANS VIEW
011_MP1.TIF CONSTRPLANS VIEW
012_P0.TIF CONSTRPLANS VIEW
013_P1.TIF CONSTRPLANS VIEW
014_P2.TIF CONSTRPLANS VIEW
015_P3.TIF CONSTRPLANS VIEW
016_E1.0.TIF CONSTRPLANS VIEW
017_E2.0.TIF CONSTRPLANS VIEW
018_E3.0.TIF CONSTRPLANS VIEW
019_E4.0.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW