Permit: T16CM04749
Permit Details
Apply Date:
06/20/2016
Applicant:
JIM PURDY
Description:
ELECTRIC RECONNECT
Outstanding Activity Conditions
Permit Number - T16CM04749
Permit Status: Expired
Permit Description: ELECTRIC RECONNECT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/20/2016 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T16CM04749
Permite Description: ELECTRIC RECONNECT
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2016 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999 * |
| 06/22/2016 | ELECTRIC - RECONNECT | N/A | Denied | 1-exposed romex at furnace room. 2- safety globe missing at porch, relocate light or have security door swing in oppisite direction. 3- provide weatherproof covers at exterior outlets. 4-smoke alarm missing in hallway. 5-the majority of this system is ungrounded,remove all grounding outletsnot grounded and replace with ungrounded outlets, this does not apply to gfci outlets. 6- cover plates missimg. 7-lights in closets within 12" of shelving require safety globes |