Inspection History Details
Inspection Status: Denied
Inspection History: ELECTRIC - RECONNECT
Permit Number - T16CM04749
Inspection Description - ELECTRIC - RECONNECT
Inspection Status - Denied
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/22/2016 | ELECTRIC - RECONNECT | Denied | IVRS - Inspection : See detailed listing on site.| 999 * |
|
| 06/22/2016 | ELECTRIC - RECONNECT | Denied | 1-exposed romex at furnace room. 2- safety globe missing at porch, relocate light or have security door swing in oppisite direction. 3- provide weatherproof covers at exterior outlets. 4-smoke alarm missing in hallway. 5-the majority of this system is ungrounded,remove all grounding outletsnot grounded and replace with ungrounded outlets, this does not apply to gfci outlets. 6- cover plates missimg. 7-lights in closets within 12" of shelving require safety globes |
|
| 06/21/2016 | ELECTRIC - RECONNECT | Denied | Home is locked, no acces. |