Permit: T15CM07324
Permit Details
Apply Date:
10/22/2015
Applicant:
N/A
Description:
CAR WASH
Architects:
- CAWLEY, SHERMAN II
Contractors:
- CONCORD GENERAL CONTRACTING INC
Permit Reviews
Permit Number - T15CM07324
Permit Status: C of o
Permit Description: CAR WASH
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
01/05/2016 | RESUBMITTAL | 01/12/2016 | COMPLETED |
01/12/2016 | RESUBMITTAL | 10/20/2016 | COMPLETED |
10/20/2016 | REVISION - - 1ST | 10/31/2016 | COMPLETED |
10/22/2015 | PLANS OK TO SUBMIT - COMM | 10/22/2015 | COMPLETED |
10/22/2015 | COMMERCIAL - NEW | 12/01/2015 | COMPLETED |
10/31/2016 | REVISION - - 2ND | 11/01/2016 | COMPLETED |
12/11/2015 | RESUBMITTAL | 01/05/2016 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T15CM07324
Permit Status: C of o
Permit Description: CAR WASH
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
10/22/2015 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T15CM07324
Permit Description: CAR WASH
Total Completed Inspections - 49
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/06/2016 | ELECTRIC - CONSTRUCTION POWER | MRAMBER | Approved | IVRS - Inspection :* |
05/27/2016 | FIRE SPKLR - UG, PIPING, HYDRO | CBASALDUA | Approved | |
06/08/2016 | FIRE SPKLR - UG PIPING FLUSH | CBASALDUA | Approved | |
06/15/2016 | ELECTRIC - UFER | RCAMACHO | Approved | IVRS - Inspection :* |
06/21/2016 | STEM WALL/RETAINING WALL | RCAMACHO | Approved | IVRS - Inspection :* |
07/20/2016 | SITE - SEWER | ESTEVEN1 | Approved | IVRS - Inspection :* |
08/04/2016 | PLUMBING - BACK WATER VALVE | RCAMACHO | Approved | PER ERNIE STEVENS OK TO BURY 3" RECLAIMED LINES 2 EACH TO INTERCEPTOR |
08/04/2016 | PLUMBING - SEWER HCS CONNECT | RCAMACHO | Approved | PER MATT RAMBER |
08/04/2016 | PLUMBING - BACK WATER VALVE | RCAMACHO | Approved | IVRS - Inspection :* |
08/04/2016 | PLUMBING - SEWER HCS CONNECT | RCAMACHO | Approved | IVRS - Inspection :* |
08/04/2016 | PLUMBING - YARD WTR LINE/TEST | RCAMACHO | Approved | IVRS - Inspection :* |
10/13/2016 | ROOF NAILING | RCAMACHO | Approved | |
10/13/2016 | REINFORCED MASONRY PRE-GROUT | RCAMACHO | Approved | |
10/26/2016 | FIRE SPKLR - OH PIPING & HYDRO | CBSALDUA | Approved | |
11/08/2016 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | |
11/08/2016 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | |
11/08/2016 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | |
11/10/2016 | PLUMBING - PRE SLAB | RCAMACHO | Approved | |
11/10/2016 | PLUMBING - ROUGH, SOIL | RCAMACHO | Approved | |
11/10/2016 | U VALUE FOR WINDOW | RCAMACHO | Approved | |
11/15/2016 | SHEET ROCK NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
11/15/2016 | FRAMING | RCAMACHO | Approved | IVRS - Inspection :* |
11/15/2016 | BUILDING PRE-SLAB | RCAMACHO | Approved | IVRS - Inspection :* |
11/16/2016 | EXCAVATION/LAYOUT REBAR & ZON | RCAMACHO | Approved | |
11/23/2016 | ELECTRIC - TEMPORARY SERVICE | MRAMBER | Approved | IVRS - Inspection :* |
11/25/2016 | TEP CLEARANCE - AM | MRAMBER | Approved | ECO |
12/12/2016 | MECHANICAL - ABOVE CEILING | RCAMACHO | Approved | |
12/12/2016 | PLUMBING - PROGRESS | RCAMACHO | Approved | |
12/12/2016 | BUILDING - PROGRESS | RCAMACHO | Approved | |
12/21/2016 | BUILDING ABOVE CEILING | RCAMACHO | Approved | |
12/21/2016 | ELECTRIC - ABOVE CEILING | RCAMACHO | Approved | |
12/21/2016 | ELECTRIC - OUTDOOR LIGHTING | RCAMACHO | Approved | |
12/21/2016 | PLUMBING - ABOVE CEILING | RCAMACHO | Approved | |
12/23/2016 | ELECTRIC - UNDERGROUND | MPUGH1 | Approved | IVRS - Inspection :* |
12/28/2016 | FIRE - ALARM FINAL | JPEELDAVIS | Approved | |
12/28/2016 | FIRE - FINAL | JPEELDAVIS | Approved | Need to mount fire extinguisher & cabinet at "detail area" north wall. Knox box required along with Knox FDC caps FACP Room sign needed Riser Room sign needed Fire Extinguisher Inside sign needed Electrical panels need labeling |
12/28/2016 | FIRE SPKLR - FINAL | JPEELDAVIS | Approved | Flow 37 Seconds |
12/29/2016 | MECHANICAL - FINAL | ESTEVEN1 | Approved | NOT READY |
12/29/2016 | PLUMBING - FINAL | ESTEVEN1 | Approved | NOT READY |
12/29/2016 | ELECTRIC - PROGRESS | ESTEVEN1 | Approved | APPROVED |
12/29/2016 | ENGINEERING - FINAL | RLEDONNE | Approved | |
12/30/2016 | RIGHT OF WAY - FINAL | DRobertson | Approved | |
01/05/2017 | SIGN - FINAL | RLEDONNE | Approved | |
01/05/2017 | PLUMBING - ROOF DRAINS | RCAMACHO | Approved | IVRS - Inspection :* |
01/05/2017 | OUTDOOR LIGHTING FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
01/05/2017 | ELECTRIC - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
01/09/2017 | NPPO - FINAL | RLEDONNE | Approved | |
01/09/2017 | LANDSCAPE - FINAL | RLEDONNE | Approved | |
01/11/2017 | BUILDING - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |