Inspection History Details
Inspection Status: Approved
Inspection History: REINFORCED MASONRY PRE-GROUT
Permit Number - T15CM07324
Inspection Description - REINFORCED MASONRY PRE-GROUT
Inspection Status - Approved
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/13/2016 | REINFORCED MASONRY PRE-GROUT | Approved | ||
10/11/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | TOP OUT TRASH ENCLOSURE AND WALL EAST OF ENCLOSURE ONLY | |
10/05/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | EXCEPT TRASH ENCLOSURE | |
10/03/2016 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
10/02/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 12' lift pw bay only | |
09/30/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/29/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/29/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | TOP OUT MAIN BLDG ONLY | |
09/28/2016 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
09/27/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/27/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 15' HEIGHT SOUTH LINTEL WALL ONLY 8' LIFT HIGH PRESSURE AREA 12" WALLS ONLY |
|
09/26/2016 | REINFORCED MASONRY PRE-GROUT | Not ready for Inspection | IVRS - Inspection :* | |
09/23/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/23/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1st lift of 12" cmu at wash bays ok | |
09/21/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/21/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 16' LIFT EAST AND NORTH WALLS TUNNEL ONLY 12' LIFT ALL WEST WALLS ONLY |
|
09/19/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/16/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/14/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/14/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 12' LIFT WASH BAY TUNNEL ONLY | |
09/13/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/13/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 2ND LIFT WEST WALLS ONLY | |
09/09/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/09/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 2nd lift at tunnel ok | |
09/02/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :*FIRST LIFT AT A.1-2 AND A.1-3 TO D.9-2 AND D.9-3. | |
09/01/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
09/01/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 4' LIFT WASH BAY ONLY | |
08/25/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | IVRS - Inspection :* | |
08/25/2016 | REINFORCED MASONRY PRE-GROUT | Partial Approval | 1- 1st lift at 8"cmu ok at wash bay 2- 1st lift at 12" cmu up to 2' ok at wash bay |