Permit: T14CM03658
Permit Details
Status:
Final
Type:
SINGLE FAMILY ADDITION
Address:
150 W MISSOURI ST
Address NEW:
150 W MISSOURI ST
Apply Date:
06/13/2014
Applicant:
OC WEALTH STRATEGIES LLC
Description:
BEDROOM EXPANSION/PLUMBING/UPGRADE ELEC/RECONNECT
Permit Reviews
Permit Number - T14CM03658
Permit Status: Final
Permit Description: BEDROOM EXPANSION/PLUMBING/UPGRADE ELEC/RECONNECT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/13/2014 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 06/19/2014 | COMPLETED |
| 07/03/2014 | REVISION - - 1ST | 07/03/2014 | COMPLETED |
| 12/29/2014 | REVISION - - 2ND | 12/29/2014 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T14CM03658
Permit Status: Final
Permit Description: BEDROOM EXPANSION/PLUMBING/UPGRADE ELEC/RECONNECT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/13/2014 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T14CM03658
Permit Description: BEDROOM EXPANSION/PLUMBING/UPGRADE ELEC/RECONNECT
Total Completed Inspections - 13
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/01/2014 | TEP CLEARANCE - AM | RCAMACHO | Approved | INCR |
| 07/01/2014 | ELECTRIC - SERVICE UPGRADE | RCAMACHO | Approved | IVRS - Inspection :* |
| 07/03/2014 | EXCAVATION/LAYOUT REBAR & ZON | RCAMACHO | Approved | IVRS - Inspection :* |
| 12/29/2014 | ROOF NAILING | CTREVIL | Approved | |
| 12/30/2014 | FRAMING | RCAMACHO | Approved | ALL BEDROOM WINDOWS TO MEET EGRESS REQUIREMENTS MIN 20"X30" NET OPEING. 5.4 (?) HEIGHT NOT TO EXCEED 44" 1. BLOCK BOOTS 3-SIDES 2. 14-3 SMOKE ALARM CIRCUIT 3. PROVIDE DEDICATED 20 AMP FRIDGE CIRCUIT 4. EGRESS WINDOWS PROVIDE MIN 20"X30" NET OPENING 5.4 (?) HEIGHT NOT TO EXCEED 44" 5. BED 2 MISSING OUTLET NORTH WALL, EXPOSED HOMERUNS. FIREBLOCK DROPPED CEILING 6. MISSING DRYER VENT 7. EXHAUST FAN BATH 8. BLOCK TUB WALLS. GROUT TUB SHOE 9. RELOCATE CONDENSOR DISCONNECT 10. GROUND METAL BOXES 11. TERMINATE CONDENSATE LINE TO EXTERIOR 12. 10-3 WATER HEATER CIRCUIT |
| 12/30/2014 | FRAMING | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/30/2014 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/30/2014 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/30/2014 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 06/01/2015 | MECHANICAL - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 06/01/2015 | PLUMBING - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 06/01/2015 | ELECTRIC - FINAL | MRAMBER | Approved | IVRS - Inspection :* |
| 06/02/2015 | BUILDING - FINAL | MRAMBER | Approved | IVRS - Inspection :* |