Permit: T14CM03658

Parcel: 120082790


Addresses:

150 W MISSOURI ST

Inspection Status: Approved

Inspection History: FRAMING

Date Description Inspector Results Comments
02/18/2015 FRAMING Approved IVRS - Inspection :*
02/10/2015 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/30/2014 FRAMING Denied IVRS - Inspection :
See detailed listing on site.| 999*
12/30/2014 FRAMING Denied ALL BEDROOM WINDOWS TO MEET EGRESS REQUIREMENTS MIN 20"X30" NET OPEING. 5.4 (?) HEIGHT NOT TO EXCEED 44"
1. BLOCK BOOTS 3-SIDES
2. 14-3 SMOKE ALARM CIRCUIT
3. PROVIDE DEDICATED 20 AMP FRIDGE CIRCUIT
4. EGRESS WINDOWS PROVIDE MIN 20"X30" NET OPENING 5.4 (?) HEIGHT NOT TO EXCEED 44"
5. BED 2 MISSING OUTLET NORTH WALL, EXPOSED HOMERUNS. FIREBLOCK DROPPED CEILING
6. MISSING DRYER VENT
7. EXHAUST FAN BATH
8. BLOCK TUB WALLS. GROUT TUB SHOE
9. RELOCATE CONDENSOR DISCONNECT
10. GROUND METAL BOXES
11. TERMINATE CONDENSATE LINE TO EXTERIOR
12. 10-3 WATER HEATER CIRCUIT
11/25/2014 FRAMING Not ready for Inspection IVRS - Inspection :*
07/14/2014 FRAMING Not ready for Inspection IVRS - Inspection :*
07/14/2014 FRAMING Not ready for Inspection NEXT NOT READY MAY RESULT IN A REFEE
07/03/2014 FRAMING Not ready for Inspection IVRS - Inspection :*