Permit: T14CM03368
Permit Details
Apply Date:
06/04/2014
Applicant:
VOGEL, BENJAMIN ARMANDO
Description:
T.I;RESTAURANT
Contractors:
- G A R CONSTRUCTION L L C
Permit Reviews
Permit Number - T14CM03368
Permit Status: Expired
Permit Description: T.I;RESTAURANT
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 06/04/2014 | COMMERCIAL - TI | 06/04/2014 | COMPLETED |
| 06/04/2014 | COMMERCIAL - TI | 07/02/2014 | COMPLETED |
| 07/18/2014 | RESUBMITTAL | 07/22/2014 | COMPLETED |
| 09/25/2015 | REVISION - - 1ST | 09/25/2015 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T14CM03368
Permit Status: Expired
Permit Description: T.I;RESTAURANT
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 06/04/2014 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Expired
Permit Number: T14CM03368
Permit Description: T.I;RESTAURANT
Total Completed Inspections - 26
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/23/2014 | ELECTRIC - ABOVE CEILING | JMILITELLO | Approved | OK TO BACKFILL PLUMBING 7 POUR CONCRETE OK TO SHEET ROCK WALLS OK FOR CEILING TILES IN FOOD PREP AREA ONLY PROVIDE ROOF JACKS AT ALL PENETRATIONS PROVIDE 2" DUCT LINER IN EXPOSED DUCT ON ROOF |
| 09/23/2014 | PLUMBING - GAS PRESSURE TEST | JMILITEL | Approved | IVRS - Inspection :* |
| 09/23/2014 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 09/23/2014 | PLUMBING - ROUGH, SOIL | JMILITEL | Approved | IVRS - Inspection :* |
| 09/23/2014 | ELECTRIC - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
| 09/23/2014 | ELECTRIC - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 09/23/2014 | FRAMING | JMILITEL | Approved | IVRS - Inspection :* |
| 10/03/2014 | SHEET ROCK NAILING | JMILITEL | Approved | IVRS - Inspection :* |
| 10/21/2014 | ELECTRIC - TEMP POWER FOR TEST | JMILITEL | Approved | IVRS - Inspection :* |
| 10/21/2014 | ELECTRIC - UFER | JMILITEL | Approved | IVRS - Inspection :* |
| 10/22/2014 | TEP CLEARANCE - AM | JMILITELLO | Approved | ECO |
| 11/05/2014 | MECHANICAL - HOODS | JMILITELLO | Approved | OK TO INSTALL KITCHEN HOOD |
| 11/05/2014 | MECHANICAL - HOODS | JMILITEL | Approved | IVRS - Inspection :* |
| 03/12/2015 | PLUMBING - PROGRESS | JMILITELLO | Approved | PROVIDE A DISCONNECT AT WALK-IN FAN COILS. PROVIDE DOME STRAINERS. CONNECT 3 COMPARTMENT SINK |
| 03/12/2015 | PLUMBING - PROGRESS | JMILITEL | Approved | IVRS - Inspection :* |
| 03/12/2015 | PLUMBING - INTERMEDIATE | JMILITEL | Approved | IVRS - Inspection :* |
| 03/12/2015 | ELECTRIC - PROGRESS | JMILITEL | Approved | IVRS - Inspection :* |
| 03/12/2015 | BUILDING ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
| 03/12/2015 | MECHANICAL - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
| 03/12/2015 | PLUMBING - ABOVE CEILING | JMILITEL | Approved | IVRS - Inspection :* |
| 10/20/2015 | PLUMBING - FINAL | JMILITEL | Approved | AIR BALANCE AND STERILIZATION REPORTS ARE OK 3 COMPARTMENT SINKS TO DRAIN SEPARATE INTO FLOOR SINKS PROVIDE PROPER REDUCER AT WATER HEATER VENT AND SCREW. |
| 10/20/2015 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 01/20/2016 | ELECTRIC - FINAL | JMILITEL | Approved | IVRS - Inspection :* |
| 01/20/2016 | ELECTRIC - OUTDOOR LIGHTING | JMILITEL | Approved | IVRS - Inspection :* |
| 01/22/2016 | FIRE - FINAL | CBASALDUA | Approved | |
| 01/25/2016 | BUILDING - FINAL | JMILITEL | Approved | IVRS - Inspection :* |