Permit: T13MH00060
Permit Details
Status:
Expired
Type:
MOBILE HOME: PRIVATE LOT
Address:
1726 W HIGGINS LN
Address NEW:
1726 W HIGGINS LN
Apply Date:
10/22/2013
Applicant:
TRINIDAD SANCHEZ CAMPA
Description:
NEW SFR/MOBILE HOME: CONNECTING UTILITY LINES.
Permit Reviews
Permit Number - T13MH00060
Permit Status: Expired
Permit Description: NEW SFR/MOBILE HOME: CONNECTING UTILITY LINES.
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 10/22/2013 | MOBILE HOME | 10/23/2013 | COMPLETED |
| 10/23/2013 | MOBILE HOME | 10/23/2013 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T13MH00060
Permit Status: Expired
Permit Description: NEW SFR/MOBILE HOME: CONNECTING UTILITY LINES.
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 10/22/2013 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T13MH00060
Permite Description: NEW SFR/MOBILE HOME: CONNECTING UTILITY LINES.
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/29/2013 | PLUMBING - FINAL | N/A | Not ready for Inspection | 1. PVC water to have minimum 12" of cover at all points. 2. ABS under trailer to be supported every four feet. 3. ABS underground to be laid on a firm bed (no bridging). 4. Changes in direction to be made with a 45 degree ell. 5. Require a two way clean out where the building drain connects to the building sewer. All downstream clean-outs to be directional. 6. PVC sch. 40 may not be installed under the mobile home. 7. AVBs on all hose bibbs. |
Completed Inspections
Permit Status: Expired
Permit Number: T13MH00060
Permit Description: NEW SFR/MOBILE HOME: CONNECTING UTILITY LINES.
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/29/2013 | TEP CLEARANCE - PM | RMYERS | Approved | |
| 11/29/2013 | ELECTRIC - RECONNECT | RMYERS | Approved | |
| 12/03/2013 | PLUMBING - YARD WTR LINE/TEST | RMYERS | Approved | |
| 12/03/2013 | PLUMBING - ROUGH, SOIL | RMYERS | Approved |