Permit: T13CM05418
Permit Details
Apply Date:
09/03/2013
Applicant:
HENRY HERNANDEZ
Description:
ELECTRIC UPGRADE UP TO 200 AMP
Permit Reviews
Permit Number - T13CM05418
Permit Status: Final
Permit Description: ELECTRIC UPGRADE UP TO 200 AMP
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 09/03/2013 | WALK THRU - RES | 09/03/2013 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T13CM05418
Permit Status: Final
Permit Description: ELECTRIC UPGRADE UP TO 200 AMP
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 09/03/2013 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T13CM05418
Permit Description: ELECTRIC UPGRADE UP TO 200 AMP
Total Completed Inspections - 4
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/21/2013 | TEP CLEARANCE - AM | MPUGH | Approved | INCR |
| 12/23/2013 | ELECTRIC - FINAL | MPUGH | Approved | #8 COPPER WIRE ONLY RATED FOR 50 AMP. PROTECT WIRE AT ITS AMPACITY. VERIFY GAS/WATER BOND. VERIFY CONDUIT FILL HAS NOT BEEN EXCEEDED ON 1 1/4 EMT. CANNOT USE OLD METER SOCKET BASE AS RACEWAY TO JUNCTION BOX. PROTECT ANY SE CABLE UP TO 8' ABOVE GRADE. |
| 12/23/2013 | ELECTRIC - FINAL | MPUGH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/23/2013 | ELECTRIC - SERVICE UPGRADE | MPUGH | Approved | IVRS - Inspection : See detailed listing on site.| 999* |