Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address NEW:
2203 E HAWTHORNE ST
Apply Date:
08/30/2013
Applicant:
DAVID PAPANIKLAS
Description:
REMODEL RES & ADD SITE WALLS
Contractors:
  • NICHOLAS BUILDING COMPANY ,

Permit Reviews

Permit Number - T13CM05405
Permit Status: Final
Permit Description: REMODEL RES & ADD SITE WALLS
Start Date Submittal Complete Date Status  
08/30/2013 RESIDENTIAL - BLDG/ZONING-WALKTHRU 08/30/2013 COMPLETED Review Details
08/30/2013 RESIDENTIAL - BLDG/WWM 09/30/2013 COMPLETED Review Details
10/02/2013 RESUBMITTAL 10/08/2013 COMPLETED Review Details
10/08/2013 RESUBMITTAL 11/05/2013 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T13CM05405
Permit Status: Final
Permit Description: REMODEL RES & ADD SITE WALLS
Total Outstanding Activity Conditions - 1
Date Name
08/30/2013 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T13CM05405
Permit Description: REMODEL RES & ADD SITE WALLS
Total Completed Inspections - 13
Date Description Inspector Results Comments
12/10/2013 PLUMBING - ROUGH, SOIL AQUIROZ Approved IVRS - Inspection :*
12/10/2013 ELECTRIC - UNDERGROUND AQUIROZ Approved IVRS - Inspection :*
12/31/2013 ELECTRIC - INTERMEDIATE MPUGH Approved USE APPROVED RACEWAY. RUN W/H CIRCUIT IN EXTERIOR LOCATIONS USE U.F.
12/31/2013 PLUMBING - GAS PRESSURE TEST MPUGH Approved IVRS - Inspection :*
12/31/2013 ELECTRIC - INTERMEDIATE MPUGH Approved IVRS - Inspection :
See detailed listing on site.| 999*
12/31/2013 FRAMING MPUGH Approved IVRS - Inspection :*
01/13/2014 SHEET ROCK NAILING MPUGH Approved IVRS - Inspection :*
01/17/2014 ELECTRIC - SERVICE UPGRADE RCANCINO Approved IVRS - Inspection :*
01/22/2014 TEP CLEARANCE - AM DSANTACR Approved INCR
04/29/2014 EXCAVATION/LAYOUT REBAR & ZON MPUGH Approved PER BLDG FINAL
04/29/2014 PLUMBING - FINAL MPUGH Approved IVRS - Inspection :*
04/29/2014 ELECTRIC - FINAL MPUGH Approved IVRS - Inspection :*
04/29/2014 BUILDING - FINAL MPUGH Approved IVRS - Inspection :*

Documents

File Name Document Type  
001_A1.0.TIF CONSTRPLANS VIEW
002_A2.0.TIF CONSTRPLANS VIEW
003_A3.0.TIF CONSTRPLANS VIEW
004_A4.0.TIF CONSTRPLANS VIEW
005_A5.0.TIF CONSTRPLANS VIEW
006_A6.0.TIF CONSTRPLANS VIEW
007_A6.1.TIF CONSTRPLANS VIEW
008_A7.0.TIF CONSTRPLANS VIEW
009_A8.0.TIF CONSTRPLANS VIEW
010_P1.0.TIF CONSTRPLANS VIEW
011_P2.0.TIF CONSTRPLANS VIEW
012_E1.0.TIF CONSTRPLANS VIEW
013_E2.0.TIF CONSTRPLANS VIEW
014_S1.0.TIF CONSTRPLANS VIEW
015_S2.0.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW