Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Permit: T13CM05096
Permit Details
Apply Date:
08/19/2013
Applicant:
PAOLO DELORENZO
Description:
NEW SFR and detached garage
Contractors:
- INNOVATIVE LIVING DESIGN AND DEVELOPMENT L L C
Permit Reviews
Permit Number - T13CM05096
Permit Status: C of o
Permit Description: NEW SFR and detached garage
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
08/19/2013 | PLANS OK TO SUBMIT - RES | 08/19/2013 | COMPLETED |
08/19/2013 | RESIDENTIAL - BLDG/ZONING/ENGINE/WWM | 09/27/2013 | COMPLETED |
10/25/2013 | REVISION - - 1ST | 10/25/2013 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T13CM05096
Permit Status: C of o
Permit Description: NEW SFR and detached garage
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
08/19/2013 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: C of o
Permit Number: T13CM05096
Permit Description: NEW SFR and detached garage
Total Completed Inspections - 28
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
10/10/2013 | ELECTRIC - UFER | MRAMBER | Approved | UFER AT REBAR OK (X2) |
10/10/2013 | ELECTRIC - UFER | MRAMBER | Approved | IVRS - Inspection :* |
10/15/2013 | STEM WALL/RETAINING WALL | RCAMACHO | Approved | IVRS - Inspection :* |
10/25/2013 | PLUMBING - SEWER HCS CONNECT | RCAMACHO | Approved | IVRS - Inspection :* |
10/25/2013 | PLUMBING - YARD WTR LINE/TEST | RCAMACHO | Approved | IVRS - Inspection :* |
10/25/2013 | PLUMBING - ROUGH, SOIL | RCAMACHO | Approved | IVRS - Inspection :* |
10/28/2013 | PLUMBING - GAS PRESSURE TEST | MRAMBER | Approved | RE-ROUTE OF GAS PIPING UNDERGROUND OK |
10/28/2013 | PLUMBING - GAS PRESSURE TEST | MRAMBER | Approved | IVRS - Inspection :* |
10/30/2013 | ELECTRIC - UNDERGROUND | MRAMBER | Approved | FLOOR BOX AT LIVING ROOM OK TO COVER |
10/30/2013 | ELECTRIC - UNDERGROUND | MRAMBER | Approved | IVRS - Inspection :* |
10/30/2013 | BUILDING PRE-SLAB | MRAMBER | Approved | IVRS - Inspection :* |
10/30/2013 | EXCAVATION/LAYOUT REBAR & ZON | MRAMBER | Approved | IVRS - Inspection :* |
11/26/2013 | REINFORCED MASONRY PRE-GROUT | RCANCINO | Approved | PURLIN SPACING CHANGED TO 48" O/C INSTEAD OF 60" O/C PER LETTER SIGNED BY PROJECT ARCHITECT. |
12/18/2013 | ROOF NAILING | RCAMACHO | Approved | 1. OK TO CRICKET MAIN HOUSE - SIMPSON P128 PURLIN ANCHORS PER DETAIL 2/A6 & & MST172 STRAPS PER DETAIL 1/A6 - OK TO COVER 2. AS BUILT REQUIRED DETAIL 2/A16 PURLIN STRAPS 48" OR NOT @ EACH SASH (?) 3. 1/2" X 10" LAG BOLTS OK AT HOUSE PORCH PER DETAIL 6/A6 OK TO COVER |
12/18/2013 | ROOF NAILING | RCAMACHO | Approved | IVRS - Inspection :* |
02/13/2014 | MECHANICAL - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
02/13/2014 | ELECTRIC - CONSTRUCTION POWER | RCAMACHO | Approved | IVRS - Inspection :* |
02/13/2014 | ELECTRIC - CABLE DROP | RCAMACHO | Approved | IVRS - Inspection :* |
02/14/2014 | PLUMBING - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
02/14/2014 | ELECTRIC - INTERMEDIATE | RCAMACHO | Approved | IVRS - Inspection :* |
02/14/2014 | FRAMING | RCAMACHO | Approved | IVRS - Inspection :* |
03/03/2014 | SHEET ROCK NAILING | RCAMACHO | Approved | KERDI INSTALLED IN LIEU OF CEMENT BOARD |
05/28/2014 | MECHANICAL - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
05/28/2014 | PLUMBING - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
05/28/2014 | OUTDOOR LIGHTING FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
05/28/2014 | ELECTRIC - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |
05/28/2014 | U VALUE FOR WINDOW | RCAMACHO | Approved | IVRS - Inspection :* |
05/29/2014 | BUILDING - FINAL | RCAMACHO | Approved | IVRS - Inspection :* |