Permit: T13CM02853
Permit Details
Apply Date:
05/13/2013
Applicant:
WATSON, JAMES RICHARD
Description:
ADD ARIZONA ROOM & REMODEL -RES
Architects:
- WATSON, JAMES RICHARD
Contractors:
- RESOLUTE BUILDERS INC
Permit Reviews
Permit Number - T13CM02853
Permit Status: Expired
Permit Description: ADD ARIZONA ROOM & REMODEL -RES
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/30/2014 | REVISION - - 1ST | 01/30/2014 | COMPLETED |
| 02/03/2014 | REVISION - - 2ND | 02/03/2014 | COMPLETED |
| 05/13/2013 | RESIDENTIAL - BLDG/ZONING-WALKTHRU | 05/13/2013 | COMPLETED |
| 05/13/2013 | RESIDENTIAL - BLDG/WWM | 08/30/2013 | COMPLETED |
| 08/30/2013 | WALK THRU - RES | 08/30/2013 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T13CM02853
Permit Status: Expired
Permit Description: ADD ARIZONA ROOM & REMODEL -RES
Total Outstanding Activity Conditions - 4
| Date | Name |
|---|---|
| 05/13/2013 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
| 06/04/2013 | ROOF TRUSSES MUST BE APPROVED PRIOR TO FRAMING INSPECTION (P2I) |
| 01/30/2014 | SPECIAL INSPECTION FOR EPOXY ANCHORS IS REQUIRED. |
| 06/04/2013 | SHOP DRAWINGS REQUIRED FOR SPIRAL STAIRCASE PRIOR TO INSTALLATION |
Completed Inspections
Permit Status: Expired
Permit Number: T13CM02853
Permit Description: ADD ARIZONA ROOM & REMODEL -RES
Total Completed Inspections - 26
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/17/2013 | EXCAVATION/LAYOUT REBAR & ZON | BBENEDON | Approved | IVRS - Inspection :* |
| 07/23/2013 | ELECTRIC - UFER | DQUINN | Approved | |
| 08/05/2013 | PLUMBING - ROUGH, SOIL | MPUGH | Approved | OK TO COVER MASTER FLOOR AREA |
| 08/05/2013 | PLUMBING - ROUGH, SOIL | MPUGH | Approved | IVRS - Inspection :* |
| 08/08/2013 | BUILDING PRE-SLAB | dquinn | Approved | |
| 09/12/2013 | ROOF NAILING | AQUIROZ | Approved | IVRS - Inspection :* |
| 09/12/2013 | EXT METAL CLIPS/EXT SHEATHING | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/25/2013 | PLUMBING - INTERMEDIATE | DQUINN | Approved | IVRS - Inspection :* |
| 10/25/2013 | FRAMING | DQUINN | Approved | IVRS - Inspection :* |
| 10/25/2013 | MECHANICAL - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/25/2013 | PLUMBING - GAS PRESSURE TEST | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/25/2013 | PLUMBING - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/25/2013 | ELECTRIC - INTERMEDIATE | AQUIROZ | Approved | IVRS - Inspection :* |
| 10/25/2013 | FRAMING | AQUIROZ | Approved | IVRS - Inspection :* |
| 12/12/2013 | ELECTRIC - CONSTRUCTION POWER | RMORENO | Approved | 1. SERVICE INSTALL NOT TO PRINT 2. 110.32 DOOR TO OPEN 90 DEGREES 3. 314.23 J BOX TO BE ANCHORED TO WALL 4. GROUND RODS MISSING, WATER & GAS BOND MISSING TOO 5. RISER STRAPPING MINI IS NOT LISTED |
| 12/12/2013 | TEP CLEARANCE - PM | LHANLY | Approved | TMPP |
| 12/12/2013 | ELECTRIC - CONSTRUCTION POWER | LHANLY | Approved | OK TO CLEAR TEMP POWER. GROUND RODS NOT REQUIRED FOR UFER SYSTEM |
| 12/12/2013 | ELECTRIC - SERVICE UPGRADE | RMORENO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 12/12/2013 | ELECTRIC - CONSTRUCTION POWER | RMORENO | Approved | IVRS - Inspection : See detailed listing on site.| 999* |
| 02/14/2014 | MECHANICAL - FINAL | AQUIROZ | Approved | 02-18-14 BLDG FINAL |
| 02/18/2014 | PLUMBING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/18/2014 | PLUMBING - GAS PRESS TEST FNL | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/18/2014 | OUTDOOR LIGHTING FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/18/2014 | ELECTRIC - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/18/2014 | BUILDING - FINAL | AQUIROZ | Approved | IVRS - Inspection :* |
| 02/18/2014 | U VALUE FOR WINDOW | AQUIROZ | Approved | IVRS - Inspection :* |