Permit: T13CM02748
Permit Details
Apply Date:
05/07/2013
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
STUDENT HOUSING- 13 STORY TOWER
Contractors:
- BEAL DERKENNE CONSTRUCTION LLC
Permit Reviews
Permit Number - T13CM02748
Permit Status: C of o
Permit Description: STUDENT HOUSING- 13 STORY TOWER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 05/07/2013 | PLANS OK TO SUBMIT - COMM | 05/08/2013 | COMPLETED |
| 05/08/2013 | COMMERCIAL - NEW | 06/20/2013 | COMPLETED |
| 06/20/2013 | RESUBMITTAL | 07/15/2013 | COMPLETED |
| 07/15/2013 | RESUBMITTAL | 08/01/2013 | COMPLETED |
| 08/01/2013 | RESUBMITTAL | 08/07/2013 | COMPLETED |
| 10/01/2013 | REVISION - - 1ST | 11/18/2013 | COMPLETED |
| 11/18/2013 | REVISION - - 1ST | 12/03/2013 | COMPLETED |
| 11/20/2013 | REVISION - - 2ND | 12/12/2013 | COMPLETED |
Completed Inspections
Permit Status: C of o
Permit Number: T13CM02748
Permit Description: STUDENT HOUSING- 13 STORY TOWER
Total Completed Inspections - 50
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/13/2013 | STEM WALL/RETAINING WALL | MPUGH | Approved | CAST IN PLACE WALLS AND COLUMNS: LEVEL P2 - OK LEVEL P1 - OK LEVEL 1 - OK LEVEL 2 - OK |
| 08/13/2013 | STEM WALL/RETAINING WALL | MPUGH | Approved | IVRS - Inspection :* |
| 09/09/2013 | BUILDING PRE-SLAB | LHANLY | Approved | LEVEL 4 SOUTH |
| 11/12/2013 | FRAMING | MPUGH | Approved | CAST IN PLACE WALLS AND COLUMNS. LEVEL 3 THRU 11, METAL SHED FRAMING FLOORS 1 & 2 |
| 11/12/2013 | FRAMING | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | PLUMBING - PROGRESS | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | MECHANICAL - HYDRONIC PIPING | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | ELECTRIC - PROGRESS | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | ELECTRIC - TEMP POWER FOR TEST | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | ELECTRIC - TEMPORARY SERVICE | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | ELECTRIC - CABLE DROP | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | ELECTRIC - UNDERGROUND | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | ELECTRIC - UFER | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | BUILDING - PROGRESS | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | U VALUE FOR WINDOW | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | STUCCO MESH | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | ROOF NAILING | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | EXT METAL CLIPS/EXT SHEATHING | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | REINFORCED MASONRY PRE-GROUT | MPUGH | Approved | IVRS - Inspection :* |
| 02/03/2014 | EXCAVATION/LAYOUT REBAR & ZON | MPUGH | Approved | IVRS - Inspection :* |
| 06/06/2014 | TEP CLEARANCE - AM | MPUGH | Approved | TEC 1217, 1216, 1215, 1214, 1213, 1212, 1211, 1210, 1208 |
| 06/09/2014 | GAS CLEARANCE | MPUGH | Approved | TEC 1308, 1310-1317 |
| 07/18/2014 | PLUMBING - GAS PRESSURE TEST | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | PLUMBING - ROOF DRAINS | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | PLUMBING - ABOVE CEILING | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | PLUMBING - INTERMEDIATE | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | MECHANICAL - ABOVE CEILING | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | MECHANICAL - INTERMEDIATE | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | OUTDOOR LIGHTING FINAL | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | ELECTRIC - FINAL | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | ELECTRIC - OUTDOOR LIGHTING | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | ELECTRIC - ABOVE CEILING | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | ELECTRIC - INTERMEDIATE | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | PLUMBING - FINAL | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | SHEET ROCK NAILING | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | FIREWALL/FIREBARRIER/FIRESTOP | MPUGH | Approved | IVRS - Inspection :* |
| 07/18/2014 | BUILDING ABOVE CEILING | MPUGH | Approved | IVRS - Inspection :* |
| 07/24/2014 | MECHANICAL - FINAL | MPUGH | Approved | IVRS - Inspection :* |
| 07/24/2014 | BUILDING - FINAL | MPUGH | Approved | IVRS - Inspection :* |
| 07/31/2014 | FIRE - ALARM FINAL | kenb | Approved | |
| 07/31/2014 | FIRE SPKLR - FINAL | kenb | Approved | |
| 07/31/2014 | FIRE SPKLR - OH PIPING & HYDRO | kenb | Approved | |
| 07/31/2014 | FIRE SPKLR - UG PIPING FLUSH | kenb | Approved | |
| 07/31/2014 | FIRE SPKLR - UG, PIPING, HYDRO | kenb | Approved | |
| 07/31/2014 | FIRE - FINAL | kenb | Approved | |
| 08/05/2014 | LANDSCAPE INSPECTION | TWOLFGAN | Approved | |
| 08/05/2014 | RIGHT OF WAY - FINAL | TWOLFGAN | Approved | |
| 08/05/2014 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 08/05/2014 | ENGINEERING - FINAL | DROBERTS | Approved | |
| 08/05/2014 | ENGINEERING - FINAL | DROBERTS | Approved |