Permit: T13CM00743
Permit Details
Apply Date:
02/07/2013
Applicant:
CATALANO, VINCENT VICTOR
Description:
TI: CHURCH
Architects:
- CATALANO, VINCENT VICTOR
Contractors:
- SPUD S BUILDING AND REMODELING L L C
Permit Reviews
Permit Number - T13CM00743
Permit Status: Expired
Permit Description: TI: CHURCH
Start Date | Submittal | Complete Date | Status |
---|---|---|---|
02/07/2013 | COMMERCIAL - TI | 02/21/2013 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T13CM00743
Permit Status: Expired
Permit Description: TI: CHURCH
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
02/07/2013 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T13CM00743
Permite Description: TI: CHURCH
Total Outstanding Inspections - 21
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
BUILDING ABOVE CEILING | N/A | Not Inspected | ||
BUILDING - PROGRESS | N/A | Not Inspected | ||
ELECTRIC - ABOVE CEILING | N/A | Not Inspected | ||
ELECTRIC - CABLE DROP | N/A | Not Inspected | ||
ELECTRIC - TEMPORARY SERVICE | N/A | Not Inspected | ||
PLUMBING - ABOVE CEILING | N/A | Not Inspected | ||
PLUMBING - GAS PRESS TEST FNL | N/A | Not Inspected | ||
PLUMBING - PROGRESS | N/A | Not Inspected | ||
PLUMBING - FINAL | N/A | Not Inspected | ||
MECHANICAL - PROGRESS | N/A | Not Inspected | ||
MECHANICAL - FINAL | N/A | Not Inspected | ||
01/27/2014 | FIRE - ALARM FINAL | N/A | Denied | Tamper failed test A/C units failed to shut down Horn/Strobe outside of crying room needs to be moved door to room when blocked open blocks the strobe. THE FOLLOWING DID PASS:: Battery test All pull stations Smoke and heat by FACP Water FLow Ground faults Horn/strobes |
03/19/2014 | FIRE SPKLR - FINAL | N/A | Denied | Need sub-contracotr to call in their permit Need tamper switch repaired - failed testing |
05/03/2013 | EXCAVATION/LAYOUT REBAR & ZON | N/A | Partial Approval | 2- F3; DETAIL #106 PAGE S1.0 OK TO POUR PROGRESS AREAS * NOTE: ACTUAL ADDRESS IS 8455 E. GOLF LINKS FAITH COMMUNITY CHURCH( METALBUILDING) OWNERS NEED TO CHANGE ADDRESS |
08/01/2013 | MECHANICAL - INTERMEDIATE | N/A | Partial Approval | IVRS - Inspection :* |
08/01/2013 | MECHANICAL - INTERMEDIATE | N/A | Partial Approval | WEST HALF OF BUILDING DUCTS - INTERIOR INSULATED |
08/01/2013 | MECHANICAL - ABOVE CEILING | N/A | Partial Approval | IVRS - Inspection :* |
11/15/2018 | PLUMBING - ROUGH, SOIL | N/A | Partial Approval | Men’s and women’s bathrooms drainage and vents, water not complete yet. |
11/22/2013 | BUILDING - FINAL | N/A | Not ready for Inspection | CONTRACTOR CANCELED - NEED FIRE FINALS |
11/22/2013 | BUILDING - FINAL | N/A | Not ready for Inspection | IVRS - Inspection :* |
11/30/2018 | ELECTRIC - INTERMEDIATE | N/A | Correction Required | Ground all metal boxes Use a junction box for all connections, install box in South wall for makeup. |
Completed Inspections
Permit Status: Expired
Permit Number: T13CM00743
Permit Description: TI: CHURCH
Total Completed Inspections - 9
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/15/2013 | ELECTRIC - UNDERGROUND | RMORENO | Approved | IVRS - Inspection :* |
08/09/2013 | PLUMBING - GAS PRESSURE TEST | JBURGE | Approved | LINE TESTED AT 15 PSI |
08/09/2013 | PLUMBING - GAS PRESSURE TEST | JBURGE | Approved | IVRS - Inspection :* |
09/17/2013 | ELECTRIC - UFER | RMORENO | Approved | IVRS - Inspection :* |
11/06/2013 | TEP CLEARANCE - PM | JBURGE | Approved | ECO VERBAL ON PHONE |
10/30/2018 | BUILDING PRE-SLAB | GWEST | Approved | ok to pour slab cut at new ground plumbing area. |
11/28/2018 | PLUMBING - INTERMEDIATE | IVR USER | Approved | IVRS - AP canceled |
11/29/2018 | FRAMING | BJONES | Approved | Water piping for restrooms 2” Copper Main |
12/13/2018 | SHEET ROCK NAILING | BJONES | Approved | No sheet rock shear in project. Explained that we no longer do this inspection. |