Permit: T12PL00075
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
4008 S WINTER PALM DR
Address NEW:
4008 S WINTER PALM DR
Apply Date:
01/12/2012
Applicant:
JESSICA MONZINGO
Description:
REPL WATER HEATER
Permit Reviews
Permit Number - T12PL00075
Permit Status: Expired
Permit Description: REPL WATER HEATER
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 01/12/2012 | PLUMBING | 01/12/2012 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T12PL00075
Permit Status: Expired
Permit Description: REPL WATER HEATER
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 01/12/2012 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T12PL00075
Permite Description: REPL WATER HEATER
Total Outstanding Inspections - 1
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/27/2012 | PLUMBING - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) AN OLD GAS FLEX CONNECTOR CANNOT BE REUSED 2) PROVIDE MINIMUM 3 SCREWS IN ALL JOINTS OF VENT CONNECTOR 3) DO NOT USE TAPE ON VENT SYSTEM 4) TAPE IS NOT TO BE USED AS A BANDAID 5) YOU CANNOT USE FLEX COPPER ON A T & P DRAIN LINE 6) MUST BE SMOOTH 3/4" INTERNAL DIAMETER 7) THE VENT CONNECTOR DOES NOT FIT PROPERLY ONTO THE DRAFT DIVERTER |