Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SOLAR WAIVER - RES
Address NEW:
8650 E WOODLAND RD
Apply Date:
12/13/2012
Applicant:
VALLEY WIDE ELECTRIC CO L L C
Description:
ROOF MOUNT SOLAR SYSTEM AND NEW SES SOLAR READY ELECTRICAL PANEL. THIS IS FOR THE HOUSE, BARN ALREADY ISSUED.
Contractors:
  • VALLEY WIDE ELECTRIC CO L L C

Permit Reviews

Permit Number - T12CM07868
Permit Status: Expired
Permit Description: ROOF MOUNT SOLAR SYSTEM AND NEW SES SOLAR READY ELECTRICAL PANEL. THIS IS FOR THE HOUSE, BARN ALREADY ISSUED.
Start Date Submittal Complete Date Status  
01/02/2013 RESIDENTIAL - BLDG/ZONING/ENGINE/WWM 01/23/2013 COMPLETED Review Details
02/22/2013 REVISION - - 1ST 02/22/2013 COMPLETED Review Details
12/13/2012 PLANS OK TO SUBMIT - RES 12/13/2012 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T12CM07868
Permit Status: Expired
Permit Description: ROOF MOUNT SOLAR SYSTEM AND NEW SES SOLAR READY ELECTRICAL PANEL. THIS IS FOR THE HOUSE, BARN ALREADY ISSUED.
Total Outstanding Activity Conditions - 1
Date Name
12/13/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T12CM07868
Permite Description: ROOF MOUNT SOLAR SYSTEM AND NEW SES SOLAR READY ELECTRICAL PANEL. THIS IS FOR THE HOUSE, BARN ALREADY ISSUED.
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
05/09/2013 BUILDING - FINAL N/A Denied 1. MAINTAIN WORKING SPACE AT PV PANEL 110.26
2. SEAL ENTRANCES ABOVE CURRENT CARRING PARTS WITH APPROVED DEVICES
3. TIGHTEN LOOSE FITTINGS & LUGS
4. NEED LABEL AT COMBINER PANEL (90.1)
5. DATA BOX AND INTERIOR PLUG STRIP NOT LISTED
6. USE APPROVED GROUNDING TERMINATIONS FOR WEEB SYSTEM 690.41-43
7. SECURE DC CONNECTORS UP UNDER MODULES
8. SECURE SUPPORTS TO ROOF WITH SEALANT
9. PLANS CALL FOR 80A PV INTERCONNECT BREAKER 150A INSTALLED
05/09/2013 BUILDING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*

Completed Inspections

Permit Status: Expired
Permit Number: T12CM07868
Permit Description: ROOF MOUNT SOLAR SYSTEM AND NEW SES SOLAR READY ELECTRICAL PANEL. THIS IS FOR THE HOUSE, BARN ALREADY ISSUED.
Total Completed Inspections - 3
Date Description Inspector Results Comments
03/04/2013 ELECTRIC - SERVICE UPGRADE DQUINN Approved IVRS - Inspection :*
06/06/2013 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :*
06/07/2013 TEP CLEARANCE - AM RMORENO Approved OK TO ENERGIZE DGC SOLAR PANEL FINAL RES 1 METER

Documents

File Name Document Type  
None DOCUMENTS VIEW
None CONSTRPLANS VIEW