Permit: T12CM07677
Permit Details
Apply Date:
12/04/2012
Applicant:
GEORGIA VANCZA
Description:
REPL GAS LINE
Contractors:
- TUCSON PLUMBING SERVICE ,
Outstanding Activity Conditions
Permit Number - T12CM07677
Permit Status: Expired
Permit Description: REPL GAS LINE
Total Outstanding Activity Conditions - 1
Date | Name |
---|---|
12/04/2012 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T12CM07677
Permite Description: REPL GAS LINE
Total Outstanding Inspections - 2
Last Inspection Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/06/2012 | PLUMBING - GAS PRESSURE TEST | N/A | Not ready for Inspection | IVRS - Inspection :* |
12/06/2012 | PLUMBING - FINAL | N/A | Not ready for Inspection | 1. No new piping. Blk iron pipe may not be installed under the building, but must be kept at least 6" above grade or structure. At the water heater: Flex may not pass thru the water heater partition. Require approved valves. No T&P relief drain. Shut off valve at cold inlet to be accessible. Unable to locate the bond between the gas and the water. No plan on site. Unable to make review. |