Permit: T12CM07393
Permit Details
Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
5001 E FAIRMOUNT ST
Address NEW:
5001 E FAIRMOUNT ST
Apply Date:
11/20/2012
Applicant:
AMITY AIR
Description:
INSTALL NEW A/C SPLIT SYSTEM
Contractors:
- AMITY AIR
Permit Reviews
Permit Number - T12CM07393
Permit Status: Final
Permit Description: INSTALL NEW A/C SPLIT SYSTEM
| Start Date | Submittal | Complete Date | Status |
|---|---|---|---|
| 11/20/2012 | WALK THRU - RES | 11/20/2012 | COMPLETED |
Outstanding Activity Conditions
Permit Number - T12CM07393
Permit Status: Final
Permit Description: INSTALL NEW A/C SPLIT SYSTEM
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 11/20/2012 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T12CM07393
Permit Description: INSTALL NEW A/C SPLIT SYSTEM
Total Completed Inspections - 3
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 11/21/2012 | MECHANICAL - INTERMEDIATE | JMILITEL | Approved | PROVISDE A MIN 6" CLEARANCE FROM COMBUSTIBLE AT FURNACE SINGLE WALL VENT ON USE DOUBLE WALL PROVIDE A TRAP IN CONDENSATE CHAIN LINE PROVIDE AN OVERFLOW SENSOR IN SECONDARY DRAIN CONNECT OVERFLOW SENSOR ON PUMP PROVIDE ELEC TO CONDENSOT PROVIDE A GFI RECEPTOR ON ROOF DO NOT USE WHITE WIRE TO POWER A/C UNIT PROVIDE A PROTECTIVE COATING ON EXPOSED ARMA FLEX AND PVC SUPPORT PVC ON ROOF EVERY 4' CONNECT PUMP HOSE INTO PVC WITH A FITTING |
| 01/01/2013 | ELECTRIC - FINAL | JMILITEL | Approved | |
| 01/11/2013 | MECHANICAL - FINAL | JMILITEL | Approved | IVRS - Inspection :* |