Permit Details

Status:
Final
Type:
SINGLE FAMILY ALTERATION
Address NEW:
4105 E 6TH ST #02
Apply Date:
10/09/2012
Applicant:
ANDREW DENNELY
Description:
REMODEL GUEST HOUSE, ADD PORCH

Permit Reviews

Permit Number - T12CM06323
Permit Status: Final
Permit Description: REMODEL GUEST HOUSE, ADD PORCH
Start Date Submittal Complete Date Status  
07/30/2013 RESIDENTIAL - BLDG/ZONING-WALKTHRU 07/30/2013 COMPLETED Review Details
07/30/2013 RESIDENTIAL - BLDG/WWM 08/22/2013 COMPLETED Review Details
08/26/2013 RESUBMITTAL 09/16/2013 COMPLETED Review Details
09/16/2013 REVISION - - 2ND 09/20/2013 COMPLETED Review Details
10/09/2012 RESIDENTIAL - BLDG/ZONING-WALKTHRU 07/30/2013 COMPLETED Review Details
10/23/2013 REVISION - - 2ND 10/23/2013 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T12CM06323
Permit Status: Final
Permit Description: REMODEL GUEST HOUSE, ADD PORCH
Total Outstanding Activity Conditions - 1
Date Name
10/09/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T12CM06323
Permit Description: REMODEL GUEST HOUSE, ADD PORCH
Total Completed Inspections - 22
Date Description Inspector Results Comments
10/16/2013 MECHANICAL - INTERMEDIATE JMILITEL Approved SEPARATE HOT & COLD WATER PIPING. INSULATE AS REQUIRED. OK TO POUR POST FOOTING. PROVIDE APPROVED DRAINAGE FITTINGS AT KITCHEN & BATH. PROVIDE PROPER VENTING AT LAUNDRY & BATH GROUP. PROVIDE TRACER WIRES IN TRENCH FOR WATER & DRAINING. PROVIDE A TEST ON ALL DWV. REMOVE REPAIR COUPLING AT YARD WATER. PROVIDE MIN 12" DEPTH AT YARD WATER. NO ADHESIVE TAPE ALLOWED ON PEX.
10/16/2013 PLUMBING - YARD WTR LINE/TEST JMILITEL Approved PROVIDE CIRCUIT FOR SMOKE DETECTOR
10/16/2013 MECHANICAL - INTERMEDIATE JMILITEL Approved IVRS - Inspection :*
10/16/2013 PLUMBING - YARD WTR LINE/TEST JMILITEL Approved IVRS - Inspection :*
10/16/2013 EXCAVATION/LAYOUT REBAR & ZON JMILITEL Approved IVRS - Inspection :*
10/25/2013 ROOF NAILING BBENEDON Approved IVRS - Inspection :*
10/29/2013 BUILDING PRE-SLAB BBENEDON Approved IVRS - Inspection :*
10/29/2013 FRAMING BBENEDON Approved IVRS - Inspection :*
10/29/2013 ELECTRIC - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
11/01/2013 PLUMBING - INTERMEDIATE BSTEVENS Approved IVRS - Inspection :*
11/01/2013 PLUMBING - ROUGH, SOIL BSTEVENS Approved IVRS - Inspection :*
11/13/2013 ELECTRIC - SERVICE UPGRADE BBENEDON Approved UNDERGROUND
11/13/2013 ELECTRIC - SERVICE UPGRADE BBENEDON Approved IVRS - Inspection :*
11/18/2013 SHEET ROCK NAILING JMILITEL Approved OK TO TAPE
11/18/2013 SHEET ROCK NAILING JMILITEL Approved IVRS - Inspection :*
12/17/2013 BUILDING - FINAL JMILITEL Approved pERMIT DOES NOT INCLUDE A UNIT 2 FOR NEW SERVICE.
PROVIDE SHIELDS OVER CANVAS CONNECTORS AT A/C UNIT.
CONVERT CONDENSATE DRAIN & PAINT EXPOSED PVC WITH LATEX PAINT.
USE AN APPROVED ELEC FITTING AT EMT CONNECTION TO ELEC DISCONNECT ON ROOF.
PROVIDE THE REQUIRED GFI SERVICE RECEPTACLE ON ROOF.
PROVIDE A SCREEN IN BATH EXHAUST T TOP.
SEPERATE GROUNDS AND NEUTRALS IN SUB PANEL.
DO NOT USE WHITE WIRE FOR POWER TO A/C UNIT
INSTALL DISHWASHER
MARK UNIT DATA PLATE WITH PROPER HEAT STRIP & FUSE ACCORDINGLY
12/17/2013 PLUMBING - FINAL JMILITEL Approved IVRS - Inspection :*
12/17/2013 OUTDOOR LIGHTING FINAL JMILITEL Approved IVRS - Inspection :*
12/17/2013 ELECTRIC - FINAL JMILITEL Approved IVRS - Inspection :*
12/17/2013 BUILDING - FINAL JMILITEL Approved IVRS - Inspection :*
12/27/2013 TEP CLEARANCE - AM JMILITEL Approved ECO 2
02/11/2014 MECHANICAL - FINAL JMILITEL Approved IVRS - Inspection :*

Documents

File Name Document Type  
001_1 OF 4.TIF CONSTRPLANS VIEW
002_2 OF 4.TIF CONSTRPLANS VIEW
003_3 OF 4.TIF CONSTRPLANS VIEW
004_4 OF 4.TIF CONSTRPLANS VIEW
None CONSTRPLANS VIEW
None DOCUMENTS VIEW