Inspection History Details
Inspection Status: Approved
Inspection History: BUILDING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/11/2014 | BUILDING - FINAL | Approved | IVRS - Inspection :* | |
| 12/17/2013 | BUILDING - FINAL | Partial Approval | IVRS - Inspection :* | |
| 12/17/2013 | BUILDING - FINAL | Partial Approval | pERMIT DOES NOT INCLUDE A UNIT 2 FOR NEW SERVICE. PROVIDE SHIELDS OVER CANVAS CONNECTORS AT A/C UNIT. CONVERT CONDENSATE DRAIN & PAINT EXPOSED PVC WITH LATEX PAINT. USE AN APPROVED ELEC FITTING AT EMT CONNECTION TO ELEC DISCONNECT ON ROOF. PROVIDE THE REQUIRED GFI SERVICE RECEPTACLE ON ROOF. PROVIDE A SCREEN IN BATH EXHAUST T TOP. SEPERATE GROUNDS AND NEUTRALS IN SUB PANEL. DO NOT USE WHITE WIRE FOR POWER TO A/C UNIT INSTALL DISHWASHER MARK UNIT DATA PLATE WITH PROPER HEAT STRIP & FUSE ACCORDINGLY |