Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
COMMERCIAL OTHER
Address NEW:
1844 W SAN MARCOS BL
Apply Date:
10/05/2012
Applicant:
JOSE LUIS PACHECO
Description:
COMMERCIAL REWIRE AND RECONNECT
Contractors:
  • TOMAHAWK ELECTRIC INC *APA*

Permit Reviews

Permit Number - T12CM06251
Permit Status: Final
Permit Description: COMMERCIAL REWIRE AND RECONNECT
Start Date Submittal Complete Date Status  
12/12/2012 COMMERCIAL - TI 12/14/2012 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T12CM06251
Permit Status: Final
Permit Description: COMMERCIAL REWIRE AND RECONNECT
Total Outstanding Activity Conditions - 1
Date Name
10/05/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T12CM06251
Permit Description: COMMERCIAL REWIRE AND RECONNECT
Total Completed Inspections - 11
Date Description Inspector Results Comments
10/08/2012 ELECTRIC - RECONNECT DSANTACR Approved IVRS - Inspection :
See detailed listing on site.| 999*
PROVIDE APPROVED PLANS AND PERMIT FOR NEW WIRING, PANELS, SERVICE EQUIP, INSIDE AND OUT. INCLUDE MECH, PLUMBING, STRUCTURE. BLD IS GUTTED OUT AT THIS TIME. YOU MAY OBTAIN TEMP POWER UNDER T.I. PERMIT, IF ELECT. MEETS CODE. USE LICENSED OR QUALIFIED ELECTRICAL.
03/20/2013 ELECTRIC - SERVICE UPGRADE DSANTACR Approved IVRS - Inspection :
See detailed listing on site.| 999*
1. PLUF UNUSED OPENING IN METER ENCLOSURE.
2. INSTALL BOND BUSHING BETWEEN METER BASE AND MAIN SERVICE DISC. SW. INSTALL R-PINS FOR FUSES.
3.SUPPORT # BARE GROUND TO STRUCTURE.
4. BOND WATE AND GAS PIPING
5. J-BOXES NEED TO HAVE CONDUCTORS TERMINATED OR CAPPED OFF.
6. CONTR. TO VERIFY 2X4 LAYING LIGHT FIXTURES LISTING COMPLIES WITH INSTALLATIONS. IT MAY NOT BE PERMISSIBLE FOR LIGHT FIXTURE TO BE SECURED TO COMBUSTIBLE MATERIAL
07/12/2013 TEP CLEARANCE - AM DSANTACR Approved TEC
11/15/2013 SHEET ROCK NAILING RCAMACHO Approved IVRS - Inspection :*
03/19/2014 ELECTRIC - INTERMEDIATE DSANTACR Approved IVRS - Inspection :*
03/19/2014 FRAMING DSANTACR Approved IVRS - Inspection :*
03/31/2014 ELECTRIC - ABOVE CEILING DSANTACR Approved PER ELEC FINAL
03/31/2014 OUTDOOR LIGHTING FINAL DSANTACR Approved IVRS - Inspection :*
03/31/2014 ELECTRIC - FINAL DSANTACR Approved IVRS - Inspection :*
03/31/2014 ELECTRIC - OUTDOOR LIGHTING DSANTACR Approved IVRS - Inspection :*
03/31/2014 BUILDING - FINAL DSANTACR Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW