Permit: T12CM04290
Permit Details
Apply Date:
07/17/2012
Applicant:
DELTA MECHANICAL INC *APA*
Description:
REPLACE INTERIOR WATER HEATER (APA)
Contractors:
- DELTA MECHANICAL INC *APA*
Outstanding Activity Conditions
Permit Number - T12CM04290
Permit Status: Final
Permit Description: REPLACE INTERIOR WATER HEATER (APA)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/17/2012 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Completed Inspections
Permit Status: Final
Permit Number: T12CM04290
Permit Description: REPLACE INTERIOR WATER HEATER (APA)
Total Completed Inspections - 1
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 12/07/2012 | PLUMBING - FINAL | BBENEDON | Approved | TYPE B VENT MAY NOT BE CUT. REPLACE DAMAGED B VENT. TAPE MAY NOT BE USED AT B VENT CONNECTION. CHECK FOR PROPER TERMINATION. RELIEF VALVE MAY DISCHARGE INTO PAN ONLY WHEN THERE IS NO GRAVITY DRAIN TO EXTERIOR. LOWER EXISTING DRAIN IN WALL AND CONNECT WH RELIEF VALVE TO IT. IF EXISTING DRAIN DOES NOT GO OUTSIDE, ALIGN DRAIN PAN TO CATCH DISCHARGE |