Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
C of o
Type:
COMMERCIAL ALTERATION
Apply Date:
07/16/2012
Applicant:
METRO TUCSON EXPEDITING & DEVELOPMENT
Description:
TI: OFFICE FOR EASTER SEALS
Architects:
  • GOLDSTEIN GENE
Contractors:
  • CAYLOR CONSTRUCTION COMPANY , RO

Permit Reviews

Permit Number - T12CM04250
Permit Status: C of o
Permit Description: TI: OFFICE FOR EASTER SEALS
Start Date Submittal Complete Date Status  
07/16/2012 COMMERCIAL - TI 07/18/2012 COMPLETED Review Details
07/18/2012 COMMERCIAL - TI 08/02/2012 COMPLETED Review Details
08/02/2012 RESUBMITTAL 08/06/2012 COMPLETED Review Details
08/21/2012 REVISION - - 1ST 08/23/2012 COMPLETED Review Details

Outstanding Activity Conditions

Permit Number - T12CM04250
Permit Status: C of o
Permit Description: TI: OFFICE FOR EASTER SEALS
Total Outstanding Activity Conditions - 1
Date Name
07/16/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: C of o
Permit Number: T12CM04250
Permit Description: TI: OFFICE FOR EASTER SEALS
Total Completed Inspections - 23
Date Description Inspector Results Comments
08/08/2012 ELECTRIC - INTERMEDIATE JBURGE Approved IVRS - Inspection :*
08/08/2012 FRAMING JBURGE Approved IVRS - Inspection :*
08/09/2012 SHEET ROCK NAILING JBURGE Approved IVRS - Inspection :*
08/09/2012 PLUMBING - PRE SLAB JBURGE Approved IVRS - Inspection :*
08/09/2012 PLUMBING - ROUGH, SOIL JBURGE Approved IVRS - Inspection :*
08/20/2012 MECHANICAL - ABOVE CEILING JMILITEL Approved IVRS - Inspection :*
08/20/2012 PLUMBING - ABOVE CEILING BBENEDON Approved IVRS - Inspection :*
08/20/2012 BUILDING ABOVE CEILING JBURGE Approved IVRS - Inspection :*
08/23/2012 ELECTRIC - ABOVE CEILING RMORENO Approved IVRS - Inspection :*
09/05/2012 RIGHT OF WAY - FINAL P.Whiddon Approved
09/10/2012 ELECTRIC - FINAL JBURGE Approved IVRS - Inspection :*
09/13/2012 FIRE SPKLR - FINAL CBASALDU Approved
09/13/2012 PLUMBING - INTERMEDIATE BBENEDON Approved IVRS - Inspection :*
09/20/2012 NPPO - FINAL MRUSSO Approved
09/20/2012 SIGN - FINAL MRUSSO Approved
09/21/2012 PLUMBING - PROGRESS BBENEDON Approved IVRS - Inspection :*
09/21/2012 PLUMBING - FINAL BBENEDON Approved IVRS - Inspection :*
09/24/2012 BUILDING - FINAL JBURGE Approved IVRS - Inspection :*
09/24/2012 MECHANICAL - FINAL JBURGE Approved IVRS - Inspection :*
09/24/2012 MECHANICAL - INTERMEDIATE JBURGE Approved IVRS - Inspection :*
09/25/2012 LANDSCAPE - FINAL MRUSSO Approved
09/26/2012 ENGINEERING - FINAL DROBERTS Approved I HAVE MET ON-SITE WITH ROB CAYLOR (444-0100) AND DISCUSSED THE ISSUES THAT HAVE BEEN RAISED BY MIKE RUSSO IN REGARDS TO THE CROSS-SLOPES IN THE HANDI-CAP SPACES. I PULLED ALL OF THE FILMS FOR MICROFISCHE TOO SEE HOW THE SITE WAS ORIGINALLY CONSTRUCTED. IN THE ORIGINAL DEVELOPMENT THESE SPACES WERE CONSTRUCTED AS REGULAR PARKING SPACES, NOTED CHANGES WERE SHOWN ON A SITE PLAN FOR A COVERED PARKING ADDITION DONE IN 2001, BUT THESE CHANGES HAVE NEVER BEEN APPROVED FROM TALKING TO THE REVIEWERS.
DISCUSSED WITH ERNIE DUARTE ABOUT THIS SITUATION AND IT HAS BEEN DECIDED THAT APPROVAL FOR THE BUILDINGS WILL BE GRANTED AT THIS TIME, AND MR.CAYLOR WILL HAVE TO COME IN AND REVISE HIS DRAWINGS TO SHOW THE HANDICAP ACCESS POINTS. THERE ARE SOME CURRENT SLOPE VALUES ON THE RAMPS THAT EXCEED THE ALLOWABLE LIMITS, SOME OF THE HANDICAP PARKING SPOTS MAY HAVE TO RE MOVED OR ELIMINATED IF THEY ARE NOT A CURRENT REQUIREMENT.
09/27/2012 FIRE - FINAL TKNAPP Approved

Documents

File Name Document Type  
C OF O_09-27-2012.TIF CERT OF OCC VIEW
001_TS.1.TIF CONSTRPLANS VIEW
002_A.1.TIF CONSTRPLANS VIEW
003_A.2.TIF CONSTRPLANS VIEW
004_A.3.TIF CONSTRPLANS VIEW
005_A.4.TIF CONSTRPLANS VIEW
006_D.1.TIF CONSTRPLANS VIEW
007_M.1.TIF CONSTRPLANS VIEW
008_M.2.TIF CONSTRPLANS VIEW
009_M.3.TIF CONSTRPLANS VIEW
010_MP-1.TIF CONSTRPLANS VIEW
011_P.1.TIF CONSTRPLANS VIEW
012_P2.TIF CONSTRPLANS VIEW
013_E1.0.TIF CONSTRPLANS VIEW
014_E2.0.TIF CONSTRPLANS VIEW
015_E2.1.TIF CONSTRPLANS VIEW
016_E3.0.TIF CONSTRPLANS VIEW
None DOCUMENTS VIEW