Permit: T12CM04236
Permit Details
Apply Date:
07/13/2012
Applicant:
SCOTT PATKA
Description:
ELEC RECONNECT (RES)
Contractors:
- RIDGEMONT PAINTING L L C
Outstanding Activity Conditions
Permit Number - T12CM04236
Permit Status: Closed
Permit Description: ELEC RECONNECT (RES)
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 07/13/2012 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Closed
Permit Number: T12CM04236
Permite Description: ELEC RECONNECT (RES)
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 07/16/2012 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) SECURITY LIGHT IN CARPORT CANNOT BE WIRED WITH ZIP CORD 2)EXTENSION CORD TAPPED INTO SERVICE CONDUCTORS NOT SAFE AND SHOULD BE REMOVED ASAP - CALL TEP TO RE-SECURE POA (SERVICE DROP) 3) DBL LUGGING AT SERVICE DISC. SW. NOT ALLOWED OUTSIDE RECEPTACLE SHOULD BE GFI PROTECTED, ALSO MISSING COVER, ALSO HAVE TEP REMOVE PAD LOCK FROM SERVIE MAIN DISCONNECT SW 4) DEMO ROMX WIRING IN MIDDLE OF BACK YARD, COULD BE HAZARD, 5) EXPOSED WIRES AT FRONT PORCH LIGHT 6) REPAIR BROKEN LIGHT SWITCHES, RECEPTACLES 7) MISSING SMOKE DETECTORS IN HALL AND BEDROOMS USE QUALIFIED OR LICENSED ELECTRICIAN |
| 07/16/2012 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |