Permit: T12CM04236

Parcel: 130180420


Addresses:

4265 E 31ST ST

Inspection Status: Denied

Inspection History: ELECTRIC - RECONNECT

Date Description Inspector Results Comments
07/16/2012 ELECTRIC - RECONNECT Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) SECURITY LIGHT IN CARPORT CANNOT BE WIRED WITH ZIP CORD
2)EXTENSION CORD TAPPED INTO SERVICE CONDUCTORS NOT SAFE AND SHOULD BE REMOVED ASAP - CALL TEP TO RE-SECURE POA (SERVICE DROP)
3) DBL LUGGING AT SERVICE DISC. SW. NOT ALLOWED OUTSIDE RECEPTACLE SHOULD BE GFI PROTECTED, ALSO MISSING COVER, ALSO HAVE TEP REMOVE PAD LOCK FROM SERVIE MAIN DISCONNECT SW
4) DEMO ROMX WIRING IN MIDDLE OF BACK YARD, COULD BE HAZARD,
5) EXPOSED WIRES AT FRONT PORCH LIGHT
6) REPAIR BROKEN LIGHT SWITCHES, RECEPTACLES
7) MISSING SMOKE DETECTORS IN HALL AND BEDROOMS
USE QUALIFIED OR LICENSED ELECTRICIAN