Permit: T12CM03010
Permit Details
Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
2749 N LOS ALTOS AV
Address NEW:
2749 N LOS ALTOS AV
Apply Date:
05/25/2012
Applicant:
MARY ANNE NICHOLS
Description:
RECONNECT ELECTRIC; RES
Outstanding Activity Conditions
Permit Number - T12CM03010
Permit Status: Expired
Permit Description: RECONNECT ELECTRIC; RES
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 05/25/2012 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T12CM03010
Permite Description: RECONNECT ELECTRIC; RES
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/29/2012 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) FILL UNUSED PORTION OF OPENING IN PANEL SIDE AND BACK 2) ONLY ONE NEUTRAL CONDUCTOR PER TERMINAL CONNECTION 3) LUG FOR GROUNDING NOT CODE COMPLIANT 250.8 & 250.12 4) INSTALL MAIN BONDING SCREW 5) SECURE CONDUIT SIDE OF PANEL 6) SMOKE DETECTORS NEEDED IN ALL BEDROOMS 7) CORDS NOT ALLOWED IN OR THRU WALLS 8) KITCHEN RECEPTS TO BE GFCI PROTECTED 9) MISSING LIGHT FIXTURE 10) FAN IN BATHROOM NOT CODE COMPLIANT 410.4 11) IT APPEARS ADDITIONS FOR BATHROOM AND STORAGE MAY HAVE BEEN BUILT WITH OUT PERMITS. PLEASE VERIFY PERMITS IF NOT MUST BE PERMITTED |
| 05/29/2012 | ELECTRIC - FINAL | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* |