Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
2749 N LOS ALTOS AV
Apply Date:
05/25/2012
Applicant:
MARY ANNE NICHOLS
Description:
RECONNECT ELECTRIC; RES

Outstanding Activity Conditions

Permit Number - T12CM03010
Permit Status: Expired
Permit Description: RECONNECT ELECTRIC; RES
Total Outstanding Activity Conditions - 1
Date Name
05/25/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T12CM03010
Permite Description: RECONNECT ELECTRIC; RES
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
05/29/2012 ELECTRIC - RECONNECT N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) FILL UNUSED PORTION OF OPENING IN PANEL SIDE AND BACK
2) ONLY ONE NEUTRAL CONDUCTOR PER TERMINAL CONNECTION
3) LUG FOR GROUNDING NOT CODE COMPLIANT 250.8 & 250.12
4) INSTALL MAIN BONDING SCREW
5) SECURE CONDUIT SIDE OF PANEL
6) SMOKE DETECTORS NEEDED IN ALL BEDROOMS
7) CORDS NOT ALLOWED IN OR THRU WALLS
8) KITCHEN RECEPTS TO BE GFCI PROTECTED
9) MISSING LIGHT FIXTURE
10) FAN IN BATHROOM NOT CODE COMPLIANT 410.4
11) IT APPEARS ADDITIONS FOR BATHROOM AND STORAGE MAY HAVE BEEN BUILT WITH OUT PERMITS. PLEASE VERIFY PERMITS IF NOT MUST BE PERMITTED
05/29/2012 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*

Documents

File Name Document Type  
None DOCUMENTS VIEW