Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
8334 E MARY DR
Address NEW:
8334 E MARY DR
Apply Date:
05/24/2012
Applicant:
ORANGUTAN HOME SERVICES, INC *APA*
Description:
REPLACE; 4 TON ROOFMOUNT GAS PACK (APA)
Contractors:
  • ORANGUTAN HOME SERVICES, INC *APA*

Outstanding Activity Conditions

Permit Number - T12CM02978
Permit Status: Expired
Permit Description: REPLACE; 4 TON ROOFMOUNT GAS PACK (APA)
Total Outstanding Activity Conditions - 1
Date Name
05/24/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T12CM02978
Permite Description: REPLACE; 4 TON ROOFMOUNT GAS PACK (APA)
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
MECHANICAL - INTERMEDIATE N/A Not Inspected
07/05/2012 MECHANICAL - FINAL N/A Denied 1. Half inch gas pipe is undersized for 98000 BTUs. install a 3/4" supply pipe, to within six feet of the gas pack. 2. Support the gas pipe. 3. Terminate condensate pipe at ground level.

Documents

File Name Document Type  
None DOCUMENTS VIEW