Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

The login landing page when selecting 'View' is still occurring and is still pending further investigation. 

Permit Details

Status:
Expired
Type:
SINGLE FAMILY ADDITION
Address NEW:
4245 E CIELO AZUL
Apply Date:
02/06/2012
Applicant:
SOLAR STORE L L C
Description:
ADDITION:ROOF MOUNTED PHOTOVLTAIC SYSTEM:RES
Contractors:
  • SOLAR STORE L L C

Permit Reviews

Permit Number - T12CM00284
Permit Status: Expired
Permit Description: ADDITION:ROOF MOUNTED PHOTOVLTAIC SYSTEM:RES
Start Date Submittal Complete Date Status  
02/06/2012 RESIDENTIAL - BLDG/ZONING-WALKTHRU 02/06/2012 COMPLETED Review Details
02/06/2012 RESIDENTIAL - BLDG/WWM 02/21/2012 COMPLETED Review Details
03/30/2012 REVISION - - 1ST 03/30/2012 ACTIVE Review Details

Outstanding Activity Conditions

Permit Number - T12CM00284
Permit Status: Expired
Permit Description: ADDITION:ROOF MOUNTED PHOTOVLTAIC SYSTEM:RES
Total Outstanding Activity Conditions - 1
Date Name
02/06/2012 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T12CM00284
Permite Description: ADDITION:ROOF MOUNTED PHOTOVLTAIC SYSTEM:RES
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
03/27/2012 BUILDING - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) GROUNDING ELECTRODE CONDUCTOR TO BE TO ALL MICRO INVERTERS
2) GEC CONNECTIONS TO BE IRREVERSIBLE 250.64
3) USE APPROVED CONNECTIONS TO JUNCTION BOX
4) PLEASE PROVIDE DETAIL FOR MISSION TILE
5) CHECK ATTIC NEXT TIME-10" RULE

Completed Inspections

Permit Status: Expired
Permit Number: T12CM00284
Permit Description: ADDITION:ROOF MOUNTED PHOTOVLTAIC SYSTEM:RES
Total Completed Inspections - 2
Date Description Inspector Results Comments
04/04/2012 ELECTRIC - FINAL RMORENO Approved IVRS - Inspection :*
04/05/2012 TEP CLEARANCE - AM JWEATHER Approved DGC CLEARED FOR "PHOTOVOLTAIC SYSTEM" PER R. MORENO

Documents

File Name Document Type  
None CONSTRPLANS VIEW
None DOCUMENTS VIEW