Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
4352 E 6TH ST
Address NEW:
4352 E 6TH ST
Apply Date:
12/01/2011
Applicant:
KURT KENNEDY
Description:
RELOCATE GAS METER FROM ALLEY TO HOUSE ON EXISTING GAS LINE R1 - REPL WATER HEATER

Outstanding Activity Conditions

Permit Number - T11PL01983
Permit Status: Expired
Permit Description: RELOCATE GAS METER FROM ALLEY TO HOUSE ON EXISTING GAS LINE R1 - REPL WATER HEATER
Total Outstanding Activity Conditions - 1
Date Name
12/01/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T11PL01983
Permite Description: RELOCATE GAS METER FROM ALLEY TO HOUSE ON EXISTING GAS LINE R1 - REPL WATER HEATER
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
12/08/2011 PLUMBING - FINAL N/A Partial Approval IVRS - Inspection :*
1) 13 PSI TEST IS OK
2) LEFT GAS CARD
3) IS USING A COMMON VENT FOR FURNACE AND WATER HEATER, THE HEATER MUST CONNECT IN THE BOTTOM OF TEE. IF YOU USE THE ABANDONED 3" DBL WALL, EXTEND IT 3' ABOVE COMBUSTION AIR INTAKE

Completed Inspections

Permit Status: Expired
Permit Number: T11PL01983
Permit Description: RELOCATE GAS METER FROM ALLEY TO HOUSE ON EXISTING GAS LINE R1 - REPL WATER HEATER
Total Completed Inspections - 1
Date Description Inspector Results Comments
12/08/2011 PLUMBING - GAS PRESSURE TEST JMILITEL Approved IVRS - Inspection :*

Documents

File Name Document Type  
None DOCUMENTS VIEW