Permit: T11PL01983

Parcel: 12610049A


Addresses:

4352 E 6TH ST

Inspection Status: Partial Approval

Inspection History: PLUMBING - FINAL

Date Description Inspector Results Comments
12/08/2011 PLUMBING - FINAL Partial Approval IVRS - Inspection :*
1) 13 PSI TEST IS OK
2) LEFT GAS CARD
3) IS USING A COMMON VENT FOR FURNACE AND WATER HEATER, THE HEATER MUST CONNECT IN THE BOTTOM OF TEE. IF YOU USE THE ABANDONED 3" DBL WALL, EXTEND IT 3' ABOVE COMBUSTION AIR INTAKE
12/02/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE A 10 PSI AIR TEST ON HOUSE PIPING
2) PROVIDE CORRECT VENTING FOR WATER HEATER/FURNACE (REPLACED WITHOUT INSPECTION)
3) PROVIDE CORRECT RELIEF DRAIN PIPING WITHOUT TRAP
4) CITY OF TUCSON HANDOUT PROVIDED
5) METER IS LOCKED OFF DUE TO LEAK