Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
3952 N 1ST AV
Apply Date:
11/29/2011
Applicant:
N/A
Description:
REPLACE:WATER HEATER (APA)
Contractors:
  • ARIZONA PLUMBING CONTRACTORS *APA*

Outstanding Activity Conditions

Permit Number - T11PL01967
Permit Status: Final
Permit Description: REPLACE:WATER HEATER (APA)
Total Outstanding Activity Conditions - 1
Date Name
11/29/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T11PL01967
Permit Description: REPLACE:WATER HEATER (APA)
Total Completed Inspections - 2
Date Description Inspector Results Comments
12/27/2011 PLUMBING - FINAL RMYERS Approved IVRS - Inspection :*
1) PROVIDE VACUUM RELEIF VALVE ON COLD INLET
2) NOT RECOMMENDED TO INTERMINGLE COPER AND GALVANZIED EVEN WITH BRASS CONNECTORS. GALVANIZED WILL BE ? OVER TIME
3) OPEN ELECTRICAL BOX NOT PERMITTED
4) NOT RELATED TO THIS INSPECTION, ALL OF THE INDIRECT WASTE PIPING CONSTITUTES AN INSANITARY CONDITION. INDIRECT WASTES FROM 3 COMP SINK AND ICE MAKER/STORAGE BIN MUST HAVE A MINIMUM 1" AIR GAP
5) MATERIALS TO BE OF APPROVED TYPE, GRAVITY DRAIN TO INDIRECT WASTE RECEPTOR
01/17/2012 PERMIT FINALED JWEATHER Approved

Documents

File Name Document Type  
None DOCUMENTS VIEW
None DOCUMENTS VIEW