Inspection History Details
Inspection Status: Approved
Inspection History: PLUMBING - FINAL
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 01/17/2012 | PLUMBING - FINAL | Approved | IVRS - Inspection :* 1) CORRECTIONS MADE OK |
|
| 01/04/2012 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) INSPECTOR STILL NOTES INSANITARY CONDITION-WILL NOTIFY HEALTH DEPT 2) WET AROUND WATER HEATER 3) PAN HALF FULL OF WATER |
|
| 12/27/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) PROVIDE VACUUM RELEIF VALVE ON COLD INLET 2) NOT RECOMMENDED TO INTERMINGLE COPER AND GALVANZIED EVEN WITH BRASS CONNECTORS. GALVANIZED WILL BE ? OVER TIME 3) OPEN ELECTRICAL BOX NOT PERMITTED 4) NOT RELATED TO THIS INSPECTION, ALL OF THE INDIRECT WASTE PIPING CONSTITUTES AN INSANITARY CONDITION. INDIRECT WASTES FROM 3 COMP SINK AND ICE MAKER/STORAGE BIN MUST HAVE A MINIMUM 1" AIR GAP 5) MATERIALS TO BE OF APPROVED TYPE, GRAVITY DRAIN TO INDIRECT WASTE RECEPTOR |
|
| 12/02/2011 | PLUMBING - FINAL | Not ready for Inspection | IVRS - Inspection :* 1) 3996 N. 1ST AVE-WILDCAT MARKET, HAS A FUNCTIONING ELECTRIC WATER HEATER, NOT AT THIS ADRESSS |