Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Permit: T11PL01967

Parcel: 11303015A


Addresses:

3952 N 1ST AV


Inspection Status: Approved

Inspection History: PLUMBING - FINAL

Permit Number - T11PL01967

Inspection Description - PLUMBING - FINAL

Inspection Status - Approved

Date Description Inspector Results Comments
01/17/2012 PLUMBING - FINAL Approved IVRS - Inspection :*
1) CORRECTIONS MADE OK
01/04/2012 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) INSPECTOR STILL NOTES INSANITARY CONDITION-WILL NOTIFY HEALTH DEPT
2) WET AROUND WATER HEATER
3) PAN HALF FULL OF WATER
12/27/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) PROVIDE VACUUM RELEIF VALVE ON COLD INLET
2) NOT RECOMMENDED TO INTERMINGLE COPER AND GALVANZIED EVEN WITH BRASS CONNECTORS. GALVANIZED WILL BE ? OVER TIME
3) OPEN ELECTRICAL BOX NOT PERMITTED
4) NOT RELATED TO THIS INSPECTION, ALL OF THE INDIRECT WASTE PIPING CONSTITUTES AN INSANITARY CONDITION. INDIRECT WASTES FROM 3 COMP SINK AND ICE MAKER/STORAGE BIN MUST HAVE A MINIMUM 1" AIR GAP
5) MATERIALS TO BE OF APPROVED TYPE, GRAVITY DRAIN TO INDIRECT WASTE RECEPTOR
12/02/2011 PLUMBING - FINAL Not ready for Inspection IVRS - Inspection :*
1) 3996 N. 1ST AVE-WILDCAT MARKET, HAS A FUNCTIONING ELECTRIC WATER HEATER, NOT AT THIS ADRESSS