Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address NEW:
1464 W KENNINGTON AV
Apply Date:
10/13/2011
Applicant:
GRISELDA MORENO
Description:
NEW:A/C UNIT:RES

Outstanding Activity Conditions

Permit Number - T11ME00297
Permit Status: Expired
Permit Description: NEW:A/C UNIT:RES
Total Outstanding Activity Conditions - 1
Date Name
10/13/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T11ME00297
Permite Description: NEW:A/C UNIT:RES
Total Outstanding Inspections - 2
Last Inspection Date Description Inspector Results Comments
10/14/2011 MECHANICAL - INTERMEDIATE N/A Partial Approval IVRS - Inspection :*
10/14/2011 MECHANICAL - FINAL N/A Partial Approval IVRS - Inspection :*
1) PROVIDE ELECTRICAL ROOF JACK
2) PVC CONDENSATE DRAIN IS TO BE BLOCKED UP OFF ROOF MINIMUM 1.5"
3) PVC CONDENSATE NOT PROPERLY TERMINATED
4) ALL PVC JOINTS ARE TO HAVE PRIMER PRIOR TO GLUE, PRIMER IS TO BE PURPLE IN COLOR
5) ALL PVC PIPE EXPOSED TO DAYLIGHT IS TO BE COATED TO PROVIDE U.V. PROTECTION

Documents