Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Expired
Type:
SINGLE FAMILY OTHER
Address:
4734 S CHERRY AV
Address NEW:
4734 S CHERRY AV
Apply Date:
12/02/2011
Applicant:
MARY ANNE NICHOLS
Description:
RECONNECT ELECTRIC; RES

Outstanding Activity Conditions

Permit Number - T11EL03113
Permit Status: Expired
Permit Description: RECONNECT ELECTRIC; RES
Total Outstanding Activity Conditions - 1
Date Name
12/02/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Outstanding Inspections

Permit Status: Expired
Permit Number: T11EL03113
Permite Description: RECONNECT ELECTRIC; RES
Total Outstanding Inspections - 1
Last Inspection Date Description Inspector Results Comments
12/06/2011 ELECTRIC - FINAL N/A Denied IVRS - Inspection :
See detailed listing on site.| 999*
1) PANEL NOT GROUNDED. INSTALL GROUND ROD SYSTEM
2) DBL LUGGED 15 AMP CIRCUIT 7. SEAL UNUSED OPENINGS IN DEADFRONT
3) SEAL KNOCKOUTS AT PANEL
4) PROTECT WIRING LAUNDRY ROOM UNDER 7' FROM PHYSICAL DAMAGE
5) OMIT HAZARDOUS EXTERIOR LIGHT FIXTURES, NOT TO CODE
6) OMIT HAZARDOUS ZIP CORD BEDROOM LIGHT FIXTURE
7) RELOCATE ANY SMOKE ALARM WITHIN 36" FORCED AIR REGISTER. SMOKE ALARM HALLWAYS
8) MISSING OUTLETS DINING ROOM
9) INSTALL ADDED 220 IN APPROVED BOXES
10) ALL PORCH ADDITIONS SHOULD BE ON RECORD AND TO INCLUDE ELECTICAL
11) NOTES 1-9 FOR POWER

Completed Inspections

Permit Status: Expired
Permit Number: T11EL03113
Permit Description: RECONNECT ELECTRIC; RES
Total Completed Inspections - 2
Date Description Inspector Results Comments
12/06/2011 ELECTRIC - RECONNECT RCAMACHO Approved IVRS - Inspection :
See detailed listing on site.| 999*
03/22/2012 TEP CLEARANCE - AM JWEATHER Approved RECN CLEARED PER R. CAMACHO

Documents

File Name Document Type  
None DOCUMENTS VIEW