Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit Details

Status:
Final
Type:
SINGLE FAMILY OTHER
Address:
1934 W ANKLAM RD
Address NEW:
1934 W ANKLAM RD
Apply Date:
11/21/2011
Applicant:
ZIMCO ELECTRIC LLC
Description:
REPAIR: ELECTRIC SUB PANEL
Contractors:
  • ZIMCO ELECTRIC LLC

Outstanding Activity Conditions

Permit Number - T11EL03004
Permit Status: Final
Permit Description: REPAIR: ELECTRIC SUB PANEL
Total Outstanding Activity Conditions - 1
Date Name
11/21/2011 PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION.

Completed Inspections

Permit Status: Final
Permit Number: T11EL03004
Permit Description: REPAIR: ELECTRIC SUB PANEL
Total Completed Inspections - 1
Date Description Inspector Results Comments
11/29/2011 ELECTRIC - FINAL LHANLY Approved PANEL OK IN CLOSET AS THIS IS A SIMPLE REPAIR OF AN EXISTING CONDITION.

GROUNDS & NEUTRALS SEPARATED

UNUSED OPENINGS AT BACK OF PANEL ARE TO EXISTING BOX BEING USED AS RACEWAY. THEY DO NOT NEED TO BE FILLED.

CABLE SHEATH IS FULL 2" INTO RACEWAY, CONDUCTORS TO BREAKER PANEL ARE NOT CLAMPED, SO THIS INSTALLATION MEETS CODE.

EXISTING SE CABLE FROM ORIGINAL INSTALLATION HAS NOT BEEN TOUCHED. OK TO LEAVE AS IS FOR THIS REPAIR.

Documents

File Name Document Type  
None DOCUMENTS VIEW