Permit: T11EL02202
Permit Details
Apply Date:
08/16/2011
Applicant:
LAURA RIOS
Description:
RECONNECT:ELECTRIC:DUPLEX
Outstanding Activity Conditions
Permit Number - T11EL02202
Permit Status: Expired
Permit Description: RECONNECT:ELECTRIC:DUPLEX
Total Outstanding Activity Conditions - 1
| Date | Name |
|---|---|
| 08/16/2011 | PLANS EXPIRE IN 180 DAYS FROM DATE OF SUBMITTAL. PERMITS EXPIRE IN 180 DAYS FROM DATE OF ISSUE OR LAST INSPECTION. |
Outstanding Inspections
Permit Status: Expired
Permit Number: T11EL02202
Permite Description: RECONNECT:ELECTRIC:DUPLEX
Total Outstanding Inspections - 2
| Last Inspection Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| ELECTRIC - FINAL | N/A | Not Inspected | ||
| 09/07/2011 | ELECTRIC - RECONNECT | N/A | Denied | IVRS - Inspection : See detailed listing on site.| 999* 1) POST ADDRESS ON BLDG VISIBLE FROM STREET 2) POST UNIT LETTER 3) HAZARDOUS WIRING AT 50 AMP CIRCUIT IN PANEL DUE TO VANDALISIM 4) LABEL CIRCUITS 5) WEATHERED COVER EXTERIOR OUTLET AT LAUNDRY 6) SUB PANEL NOT MAINTAINED IN WORKING CONDITION, HAVE QUALIFIED ELECTRICIAN OMIT VIOLATIONS 7) EXPOSED CONDUCTOR EXTERIOR OUTLET AT WATER HEATER 8) SECURE OUTLET DINING ROOM TO WALL 9) SMOKE ALARM BEDROOMS AND HALLWAY 10) 2 WIRE OUTLETS AND 2 WIRE OUTLETS WITH GROUND MIXED THROUGHOUT 11) WATER HEATER NOT TO CODE |